Latest GHS Classification Results by the Japanese Government (edited by NITE)

Japanese



GENERAL INFORMATION
 
Item Information
CAS RN 110-01-0
Chemical Name Tetrahydrothiophene
Substance ID m-nite-110-01-0_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) MHLW Website (in Japanese Only)
Sample SDS by MHLW (External link) MHLW Website (in Japanese Only)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified (Not applicable)
-
-
- - There are no chemical groups associated with explosive properties present in the molecule. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
2 Flammable gases Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
3 Aerosols Not classified (Not applicable)
-
-
- - Not an aerosol product. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Oxidizing gases Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
5 Gases under pressure Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
6 Flammable liquids Category 2


Danger
H225 P303+P361+P353
P370+P378
P403+P235
P210
P233
P240
P241
P242
P243
P280
P501
A flash point of 13 degrees C [closed-cup] (IMDG (2008)) is < 23 degrees C, and an initial boiling point of 119 to 121 degrees C is > 35 degrees C, therefore, it corresponds to Category 2.
Besides, it is classified in 3PGII in UNRTDG (UN2412).
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
7 Flammable solids Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
8 Self-reactive substances and mixtures Not classified (Not applicable)
-
-
- - Containing neither chemical groups related to explosibility nor those related to self-reactivity. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
9 Pyrophoric liquids Not classified
-
-
- - It is conceivable that it does not ignite at normal temperatures from an auto-ignition temperature: 200 degrees C (ICSC (1998)). FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
10 Pyrophoric solids Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
11 Self-heating substances and mixtures Classification not possible
-
-
- - No established test method suitable for liquid substances. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - Not containing metals or semimetals (B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
13 Oxidizing liquids Not classified (Not applicable)
-
-
- - An organic compound that does not contain oxygen, fluorine, or chlorine. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
14 Oxidizing solids Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
15 Organic peroxides Not classified (Not applicable)
-
-
- - An organic compound that does not contain -O-O- structure. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
16 Corrosive to metals Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Category 4


Warning
H302 P301+P312
P264
P270
P330
P501
On the basis of an LD50 value of 1850 mg/kg for rats (FIFRA, GLP compliance) (IUCLID (2000)), it was classified in Category 4. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Dermal) Not classified
-
-
- - From an LD50 value of >2000 mg/kg and no death in the administration of 2000 mg/kg to rabbits (FIFRA, GLP compliance) (IUCLID (2000)), it was classified as "Not classified." FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Vapours) Category 4


Warning
H332 P304+P340
P261
P271
P312
On the basis of an LC50 value of 6270 ppm/4h for rats (Federal Register 44 (145), GLP compliance) (IUCLID (2000)), it was classified in Category 4.
Besides, a reference value of gasses was applied because the LC50 value (6270 ppm) is lower than 90 % of the saturated vapour pressure concentration (23692 ppm).
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Dusts and mists) Not classified
-
-
- - On the basis of an LC50 value of 155 mg/L/1h = 38.75 mg/L/4h for rats (IUCLID (2000)), it was classified as "Not classified."
Besides, it was considered to be a test by mist because the toxicity value (155 mg/L) was higher than the saturated vapour pressure concentration (85 mg/L).
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
2 Skin corrosion/irritation Classification not possible
-
-
- - A test using rabbits (FHSA compliance) evaluates this substance as not a skin irritant (HSDB (2003), ITC/USEPA; Information Review #307 (1982)).
On the other hand, it is classified in Xi; R38, Skin Irrit.2 in EU (EC-JRC (ESIS) (Access on Jan. 2011)), which is a conflicting result.
It was classified as "Classification not possible" due to no other information.
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
3 Serious eye damage/eye irritation Classification not possible
-
-
- - A test using rabbits (FHSA compliance) evaluates this substance as not an eye irritant because it does not induce local inflammatory reaction (HSDB (2003), ITC/USEPA; Information Review #307 (1982)),
On the other hand, it is classified in Xi; R36, Eye Irrit.2 in EU (EC-JRC (ESIS) (Access on Jan. 2011)), which is a conflicting result.
It was classified as "Classification not possible" due to no other information.
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Respiratory sensitization Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Skin sensitization Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
5 Germ cell mutagenicity Classification not possible
-
-
- - The classification is not possible due to no in vivo test data.
Besides, negatives were reported in all of an Ames test (OECD TG471, GLP compliance), an HGPRT test using CHO cells (OECD TG476, GLP compliance), and a chromosomal aberration test using human lymphocyte as in vitro tests (JECFA No.1146 (2008)).
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
6 Carcinogenicity Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
7 Reproductive toxicity Classification not possible
-
-
- - An inhalation exposure test to pregnant rats during an organogenetic period (GLP compliance) reports no teratogenicity and no effect on a fetus (IUCLID (2000)), but effects on sexual function and fertility are not able to be judged due to no data, therefore, it was classified as "Classification not possible." FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
8 Specific target organ toxicity - Single exposure Classification not possible
-
-
- - Lack of data.
Besides, information that workers at a factory producing this substance complained of headache palpitations, giddiness, general feeling of being unwell after a short exposure (HSDB (2003)), the necropsy after deaths in oral administration to rats found changes in lung, stomach, and intestines in animal tests (IUCLID (2000)), and inhalation exposure to rats caused slight lacrimation, peripheral vasodilation, and ataxia was reported, but further details of which are unknown.
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - A 90-day vapour inhalation test (OECD, GLP compliance), in which rats were exposed to concentrations up to maximal 1500 ppm/6h (5.41 mg/L/6h) reported only a slight irritant, but no serious adverse effect, and NOAEL of 50 ppm (0.18 mg/L/6h) (IUCLID (2000)) without further details.
The classification is not possible due to lack of data as a basis for classification.
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
10 Aspiration hazard Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
11 Hazardous to the aquatic environment Long term (Chronic) Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
12 Hazardous to the ozone layer Classification not possible
-
-
- - This substance is not listed in Annexes to the Montreal Protocol. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information