Latest GHS Classification Results by the Japanese Government (edited by NITE)

Japanese



GENERAL INFORMATION
 
Item Information
CAS RN 123-11-5
Chemical Name p-Anisaldehyde
Substance ID m-nite-123-11-5_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) To Workplace Safety Site (MHLW)
Sample SDS by MHLW (External link) To Workplace Safety Site (MHLW)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified (Not applicable)
-
-
- - There are no chemical groups associated with explosive properties present in the molecule. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
2 Flammable gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
3 Aerosols Not classified (Not applicable)
-
-
- - Not aerosol products. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Oxidizing gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
5 Gases under pressure Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
6 Flammable liquids Not classified
-
-
- - Although measurement method of the flash point 121 degC is unknown (HSDB (2003)), it is estimated that the flash point measured by the closed-cup method is >= 93 degC. Therefore, the substance is classified as "Not classified". FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
7 Flammable solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
8 Self-reactive substances and mixtures Not classified (Not applicable)
-
-
- - There are no chemical groups present in the molecule associated with explosive or self-reactive properties. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
9 Pyrophoric liquids Classification not possible
-
-
- - No data available. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
10 Pyrophoric solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
11 Self-heating substances and mixtures Classification not possible
-
-
- - Test methods applicable to liquid substances are not available. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - The chemical structure of the substance does not contain metals or metalloids (B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
13 Oxidizing liquids Not classified (Not applicable)
-
-
- - The substance is an organic compound containing oxygen which is chemically bonded only to carbon or hydrogen. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
14 Oxidizing solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
15 Organic peroxides Not classified (Not applicable)
-
-
- - Organic compounds containing no bivalent -O-O- structure. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
16 Corrosive to metals Classification not possible
-
-
- - No data available. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Not classified
-
-
- - Based on the report that the administration of 2000 mg/kg for rats caused no mortality, and the estimated LD50 value was > 2000 mg/kg ("Toxicity Testing Reports of Environmental Chemicals" (Chemicals Investigation Promoting Council) (2000)), the substance was classified as "Not classified". FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Dermal) Not classified
-
-
- - Based on the rabbit LD50 value of > 5000 mg/kg (BUA 250 (2004)), the substance was classified as "Not classified". FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Vapours) Classification not possible
-
-
- - It was reported that the rat LC50 values (male and female) were more than 0.32 mg/L (vapor) (SIAP (2009)). Since the exposure time was unknown, the classification was not possible. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Dusts and mists) Classification not possible
-
-
- - No data available. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
2 Skin corrosion/irritation Not classified
-
-
- - Negative results of human patch test were reported (SIAP (2009)). In the rabbit test, occlusive application of the substance caused slightly irritation after 4 hours of application, but symptoms were all disappeared within 8 days. Based on these documents, the substance was classified as "Not classified" in the JIS classification (corresponding to Category 3 in the UN-GHS classification). FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
3 Serious eye damage/eye irritation Not classified
-
-
- - The substance was classified as "Not classified" based on the documented case of "non-irritating" from rabbit test in which slight irritation was noted, but symptoms disappeared within 72 hours (SIAP (2009)). FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Respiratory sensitization Classification not possible
-
-
- - No data available. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Skin sensitization Not classified
-
-
- - In the maximization test on 25 volunteers, the substance was not sensitizing. The result of the LLNA test (OECD TG 429 and EPA OPPTS 870.2600) using mice was also negative. The substance was concluded to be non-sensitizer to the skin (SIAP (2009)). Based on the document, the substance was classified as "Not classified". FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
5 Germ cell mutagenicity Classification not possible
-
-
- - The classification was not possible due to lack of in vivo test data. As relevant information, as for in vitro studies, negative results in the Ames test and in the chromosome aberration test using CHL cells ("Toxicity Testing Reports of Environmental Chemicals" (Chemicals Investigation Promoting Council), (Access on May 2010)) and others were reported. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
6 Carcinogenicity Classification not possible
-
-
- - No data available. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
7 Reproductive toxicity Category 2


Warning
H361 P308+P313
P201
P202
P280
P405
P501
In the combined repeated oral dose toxicity study with the reproduction/developmental toxicity screening test in rats (OECD TG 422), decrease of the fertility index, number of pups born, delivery index, and number of pups alive were noted at the dose (500 mg/kg) in which general toxicity such as transitory salivation and hypertrophy of hepatocyte to parent animals was observed ("Toxicity Testing Reports of Environmental Chemicals" (Chemicals Investigation Promoting Council) (Access on Oct. 2010)). Therefore, the substance was classified as Category 2. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
8 Specific target organ toxicity - Single exposure Classification not possible
-
-
- - In the acute oral toxicity study in rats (OECD TG 401), no treatment-related changes of clinical signs were observed in all treatment groups, and the values of body weight gain in both sexes at 2000 mg/kg were slightly decreased only on day 2 of observation. In the findings at necropsy conducted on day 15 of observation period, no abnormalities were observed in all animals ("Toxicity Testing Reports of Environmental Chemicals" (Chemicals Investigation Promoting Council) (Access on Oct. 2010)). According to the results of the report, although classification was equivalent to "Not classified" category in oral route, the classification for specific target organ toxicity (single exposure) was concluded as "Classification not possible" because the effects for the other routes were unknown due to no data available. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - In the combined repeated oral dose toxicity study with the reproduction/developmental toxicity screening test in rats (OECD TG 422), the changes observed were as follows: increased liver weights, elevations of the liver-derived enzyme activities in the serum, and centrilobular hepatocellular hypertrophy at 500 mg/kg/day (converted dose level as that of 90-day study: approx. 235 mg/kg/day), significant decreases in platelet counts at 100 mg/kg/day (converted dose level as that of 90-day study: approx. 47 mg/kg/day) or more, and hyperplasia of squamous epithelium in the forestomach in all rats at 500 mg/kg/day and three rats at 100 mg/kg/day ("Toxicity Testing Reports of Environmental Chemicals" (Chemicals Investigation Promoting Council) (Access on Oct. 2010)). However, the toxic effects at the upper limit of the guidance values (100 mg/kg/day) remained unknown due to lack of sufficient data. Therefore, the substance was classified as "Classification not possible". FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
10 Aspiration hazard Classification not possible
-
-
- - No data available. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Category 3
-
-
H402 P273
P501
Classified into Category 3 from its 96h-LC50 = 40 mg/L for fish (Oryzias latipes) (Test for the Ecological Effect of Chemical Substances (Ministry of the Environment), 1999). FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
11 Hazardous to the aquatic environment Long term (Chronic) Not classified
-
-
- - Classified as "Not classified" since it is rapidly degradable (Readily biodegradable, BOD degradation rate: 99% (Biodegradation and Bioconcentration of Existing Chemical Substances under the Chemical Substances Control Law, 2001)) and its bioaccumulation potential is estimated to be low (Log Kow = 1.79 (PHYSPROP Database, 2009)) though its acute toxicity is Category 3. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)
12 Hazardous to the ozone layer Classification not possible
-
-
- - This substance is not listed in Annexes to the Montreal Protocol. FY2010 GHS Classification Guidance by the Japanese Government (July, 2010)


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information