Item | Information |
---|---|
CAS RN | 1309-37-1 |
Chemical Name | Diiron trioxide |
Substance ID | m-nite-1309-37-1_v1 |
Download of Excel format | Excel file |
Item | Information |
---|---|
Guidance used for the classification (External link) | To Guidance List |
UN GHS document (External link) | To UN GHS document |
FAQ(GHS classification results by the Japanese Government) | To FAQ |
List of Information Sources (Excel file) | List of Information Sources |
List of Definitions/Abbreviations | Definitions/Abbreviations |
Sample Label by MHLW (External link) | MHLW Website (in Japanese Only) |
Sample SDS by MHLW (External link) | MHLW Website (in Japanese Only) |
OECD/eChemPortal (External link) | To OECD/eChemPortal (External link) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Explosives | Not classified (Not applicable) |
- |
- | - | There are no chemical groups associated with explosive properties present in the molecule. It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
2 | Flammable gases | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition). It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
3 | Aerosols | Not classified (Not applicable) |
- |
- | - | Not aerosol products. It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
4 | Oxidizing gases | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition). It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
5 | Gases under pressure | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition). It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
6 | Flammable liquids | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition). It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
7 | Flammable solids | Not classified |
- |
- | - | It was classified as "Not classified" from information that it is not combustible (ICSC (2004)). | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
8 | Self-reactive substances and mixtures | Not classified (Not applicable) |
- |
- | - | There are no chemical groups associated with explosive or self-reactive properties present in the molecule. It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
9 | Pyrophoric liquids | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition). It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
10 | Pyrophoric solids | Not classified |
- |
- | - | It was classified as "Not classified" from information that it is not combustible (ICSC (2004)). | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
11 | Self-heating substances and mixtures | Not classified |
- |
- | - | It was classified as "Not classified" from information that it is not combustible (ICSC (2004)). | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
12 | Substances and mixtures which, in contact with water, emit flammable gases | Not classified |
- |
- | - | It is a metal compound, but it was classified as "Not classified" because it is estimated that it does not react vigorously with water from information that it is insoluble in water (ICSC (2004)). | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
13 | Oxidizing liquids | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition). It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
14 | Oxidizing solids | Classification not possible |
- |
- | - | It is an inorganic compound containing oxygen (but not halogen). However, the classification is not possible due to no data. | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
15 | Organic peroxides | Not classified (Not applicable) |
- |
- | - | Inorganic compound. It was classified as "Not classified (Not applicable)." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
16 | Corrosive to metals | Classification not possible |
- |
- | - | Classification is not possible because test methods applicable to solid substances are not available. | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
17 | Desensitized explosives | Not classified |
- |
- | - | There are no chemical groups associated with explosive properties present in the molecule. It was classified as "Not classified." | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Acute toxicity (Oral) | Not classified |
- |
- | - | [Rationale for the Classification] Based on (1) and (2), it was classified as "Not classified." [Evidence Data] (1) LD50 for rats: > 15,000 mg/kg (JECFA FAS6 (1975)) (2) LD50 for rats: > 10,000 mg/kg (HSDB (Access on July 2019)) [Reference Data, etc.] (3) LD50 for mice: > 15,000 mg/kg (JECFA FAS6 (1975)) |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Dermal) | Classification not possible |
- |
- | - | [Rationale for the Classification] Classification not possible due to lack of data. |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Inhalation: Gases) | Not classified (Not applicable) |
- |
- | - | [Rationale for the Classification] Solid (GHS definition). It was classified as "Not classified (Not applicable)." |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Inhalation: Vapours) | Classification not possible |
- |
- | - | [Rationale for the Classification] Classification not possible due to lack of data. |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Inhalation: Dusts and mists) | Not classified |
- |
- | - | [Rationale for the Classification] Based on (1), it was classified as "Not classified." [Evidence Data] (1) Inhalation exposure with rats (4 hours, dust) : no death at more than 5.05 mg/L (REACH registration dossier (Access on August 2019)) |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
2 | Skin corrosion/irritation | Not classified |
- |
- | - | [Rationale for the Classification] Based on (1), it was classified as "Not classified." Besides, the classification was changed using the new data obtained. [Evidence Data] (1) In a skin irritation test with rabbits conducted according to OECD TG 404 (4-hour semi-occlusive application), no skin reaction was observed, and the mean scores for erythema and edema were 0 for 24/48/72 hours (REACH registration dossier (Access on August 2019)). |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
3 | Serious eye damage/eye irritation | Not classified |
- |
- | - | [Rationale for the Classification] Based on (1), it was classified as "Not classified." Besides, since IUCLID (2000), which was the basis for the previous classification, cannot be currently confirmed, the classification was changed based on the new data. [Evidence Data] (1) In an eye irritation test with rabbits conducted according to OECD TG 405, it was reported that the irritation score at 24/48/72 hours was 0, indicating no irritation (REACH registration dossier (Access on August 2019)). [Reference Data, etc.] (2) In an eye irritation test with rabbits conducted according to OECD TG 405 (but with an application volume of 30 mg), it was reported that the irritation score at 24/48/72 hours was 0, indicating no irritation (REACH registration dossier (Access on August 2019)). |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
4 | Respiratory sensitization | Classification not possible |
- |
- | - | [Rationale for the Classification] Classification not possible due to lack of data. |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
4 | Skin sensitization | Classification not possible |
- |
- | - | [Rationale for the Classification] There is data of (1), however, classification was not possible due to lack of data. [Evidence Data] (1) In a skin sensitization test with guinea pigs (Maurer optimization test, intradermal induction: 0.1% x 10 injections), no skin reaction was observed and it was concluded to be negative (REACH registration dossier (Access on August, 2019)). |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
5 | Germ cell mutagenicity | Not classified |
- |
- | - | [Rationale for the Classification] Based on (1) and (2), since negative findings were observed in in vivo and in vitro tests, it was classified as "Not classified." [Evidence Data] (1) As for in vivo, there are negative reports in a comet assay and an unscheduled DNA synthesis test with rats (HSDB (Access on July 2019)). (2) As for in vitro, there are negative reports in bacterial reverse mutation tests and a chromosomal aberration test with cultured mammalian cells (HSDB (Access on July 2019)). |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
6 | Carcinogenicity | Classification not possible |
- |
- | - | [Rationale for the Classification] Based on classification results by other organizations in (1), it was classified as "Classification not possible" in accordance with the GHS Classification Guidance for the Japanese Government. [Evidence Data] (1) As for classification results by domestic and international organizations, it was classified in Group 3 by IARC (IARC Suppl 7 (1987)), in A4 by ACGIH (ACGIH (7th, 2006)). [Reference Data, etc.] (2) Some studies on metal workers exposed to the dusts of this substance have shown an increased incidence of lung cancer, but the influence of factors other than ferric oxide (soots, silica and asbestos in foundry work) cannot be discounted. In other studies on metal and chemical workers exposed to this substance, the incidence of lung cancer was not increased (IARC Suppl 7 (1987)). (3) No carcinogenic effect due to this substance by itself was observed in tests which mice, hamsters or guinea-pigs were given ferric oxide intratracheally or by inhalation (IARC Suppl 7 (1987), ACGIH (7th, 2006)). |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
7 | Reproductive toxicity | Classification not possible |
- |
- | - | [Rationale for the Classification] Classification not possible due to lack of data. |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
8 | Specific target organ toxicity - Single exposure | Category 1 (respiratory organs) |
Danger |
H370 | P308+P311 P260 P264 P270 P321 P405 P501 |
[Rationale for the Classification] Based on (1) to (3), since it was presumed to be probable that inhalation of this substance causes respiratory symptoms and pulmonary inflammation in humans, it was classified as Category 1 (respiratory organs). By using the new information, the category was changed from the previous classification. [Evidence Data] (1) Fume fever with cold-like symptoms such as fever, chills, pain, chest tightness and coughing may occur due to exposure to the dust or fume of this substance (HSDB (Access on July 2019)). (2) When 10 volunteers were given 5 mg of the particles of this substance (particle size: 2.6 micrometer) by single instillation into the lung with the use of a bronchoscope, a transient inflammatory response (an increased number of neutrophils and alveolar macrophages, and increased amounts of protein, lactate dehydrogenase and interleukin-8 in bronchoalveolar lavage fluid) was observed in the lung (ACGIH (7th, 2006), HSDB (Access on July 2019)). (3) Although the number of exposures was not described, there is a report that 3 men exposed to the welding fumes of this substance developed coughing and shortness of breath, and diffuse fibrosis in the lungs by X-ray examination (HSDB (Access on July 2019)). |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
9 | Specific target organ toxicity - Repeated exposure | Category 1 (respiratory organs) |
Danger |
H372 | P260 P264 P270 P314 P501 |
[Rationale for the Classification] Based on (1) and (2), since effects on the lungs in humans were observed on inhalation, it was classified as Category 1 (respiratory organs). [Evidence Data] (1) Inhalation of dust containing this substance causes siderosis (a harmless form of pneumoconiosis) in the lungs (ACGIH (7th, 2006), DFGOT vol.2 (1991)). (2) Six to 10 years of exposure to iron oxide fume is required in order to produce siderosis. Pulmonary siderosis is considered a benign condition and does not progress to fibrosis. Little or no clinical change was found in workers diagnosed with pulmonary siderosis (ACGIH (7th, 2006)). [Reference Data, etc.] (3) A number of workers with exposure to mixed substances containing this substance developed pneumoconiosis. There is a report that workers exposed to iron oxide fume and silica may develop "a mixed dust pneumoconiosis" (ACGIH (7th, 2006)). |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
10 | Aspiration hazard | Classification not possible |
- |
- | - | [Rationale for the Classification] Classification not possible due to lack of data. |
FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
11 | Hazardous to the aquatic environment Short term (Acute) | Classification not possible |
- |
- | - | Classification not possible due to lack of data. | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
11 | Hazardous to the aquatic environment Long term (Chronic) | Classification not possible |
- |
- | - | Classification not possible due to lack of data. | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
12 | Hazardous to the ozone layer | Classification not possible |
- |
- | - | Classification not possible due to lack of data. | FY2019 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
|