Item | Information |
---|---|
CAS RN | 1309-48-4 |
Chemical Name | Magnesium oxide |
Substance ID | m-nite-1309-48-4_v1 |
Download of Excel format | Excel file |
Item | Information |
---|---|
Guidance used for the classification (External link) | To Guidance List |
UN GHS document (External link) | To UN GHS document |
FAQ(GHS classification results by the Japanese Government) | To FAQ |
List of Information Sources (Excel file) | List of Information Sources |
List of Definitions/Abbreviations | Definitions/Abbreviations |
Sample Label by MHLW (External link) | MHLW Website (in Japanese Only) |
Sample SDS by MHLW (External link) | MHLW Website (in Japanese Only) |
OECD/eChemPortal (External link) | To OECD/eChemPortal (External link) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Explosives | Not classified (Not applicable) |
- |
- | - | There are no chemical groups present in the molecule associated with explosive properties. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
2 | Flammable gases | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
3 | Aerosols | Not classified (Not applicable) |
- |
- | - | Not an aerosol product. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
4 | Oxidizing gases | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
5 | Gases under pressure | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
6 | Flammable liquids | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
7 | Flammable solids | Not classified |
- |
- | - | It is not combustible (ICSC (2010)). | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
8 | Self-reactive substances and mixtures | Not classified (Not applicable) |
- |
- | - | There are no chemical groups present in the molecule associated with explosive or self-reactive properties. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
9 | Pyrophoric liquids | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
10 | Pyrophoric solids | Not classified |
- |
- | - | It is not combustible (ICSC (2010)). | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
11 | Self-heating substances and mixtures | Not classified |
- |
- | - | It is not combustible (ICSC (2010)). | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
12 | Substances and mixtures which, in contact with water, emit flammable gases | Not classified |
- |
- | - | It is estimated that it does not react vigorously with water from water solubility data measured (water solubility: 86 mg/L (30 degrees C), HSDB (Access on June 2015)). | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
13 | Oxidizing liquids | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
14 | Oxidizing solids | Classification not possible |
- |
- | - | It is an inorganic compound which does not contain halogen but contains oxygen. The classification is not possible due to no data. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
15 | Organic peroxides | Not classified (Not applicable) |
- |
- | - | It is an inorganic compound. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
16 | Corrosive to metals | Classification not possible |
- |
- | - | No established test method suitable for solid substances. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
17 | Desensitized explosives | - |
- |
- | - | - | - | - |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Acute toxicity (Oral) | Not classified |
- |
- | - | From reported LD50 values of 3,870 mg/kg (males) and 3,990 mg/kg (females) for rats (HSDB (Access on June 2015)), it was classified as "Not classified" (Category 5 in the classification criteria of UN GHS). | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Dermal) | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Inhalation: Gases) | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Inhalation: Vapours) | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Inhalation: Dusts and mists) | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
2 | Skin corrosion/irritation | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
3 | Serious eye damage/eye irritation | Category 2 |
Warning |
H319 | P305+P351+P338 P337+P313 P264 P280 |
Based on the information that a slight irritation of the eye was observed in 95 workers exposed to the dust of this substance (an unknown concentration) (ACGIH (7th, 2003)), it was classified in Category 2. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
4 | Respiratory sensitization | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
4 | Skin sensitization | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
5 | Germ cell mutagenicity | Classification not possible |
- |
- | - | The classification is not possible due to lack of data. There is no in vivo data. As for in vitro, it is reported that a bacterial reverse mutation test was negative (ACGIH (7th, 2003), HSDB (Access on June 2015)). | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
6 | Carcinogenicity | Classification not possible |
- |
- | - | As for humans, it is reported that excess cancers occurred in multiple organs by combined occupational exposure to this substance and others, and specific tumors formed in exposure to this substance were the lip, stomach, and lung cancers based on the standardized incidence ratio (SIR). However, it is described that the interpretation of this result is limited because the number of subjects were small and the level and duration of exposure to magnesium oxide were unknown (ACGIH (7th, 2003)). Besides, there is no evidence of carcinogenicity in humans by an inhalation route of magnesium oxide dust or fumes. It is pointed out that the increased frequency of lung cancer observed in welders in the past is likely caused by exposure to hexavalent chromium, not magnesium oxide (DFGOT vol. 2 (1991)). As for experimental animals, it is described that the substance was intratracheally applied in hamsters at a dose of 2mg/week for 30 weeks and observed for up to 100 weeks and as a result, the number of histiocytic lymphomas increased (ACGIH (7th, 2003)). However, there is no carcinogenicity test report according to the standard guidelines. From the above, ACGIH classified this substance in A4 in carcinogenicity. Also in this classification, the substance was classified as "Classification not possible" in this hazard class due to lack of data. |
FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
7 | Reproductive toxicity | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
8 | Specific target organ toxicity - Single exposure | Category 3 (Respiratory tract irritation) |
Warning |
H335 | P304+P340 P403+P233 P261 P271 P312 P405 P501 |
It is reported that this substance is irritating to the respiratory tract (ACGIH (7th, 2003), DFGOT vol. 2 (1991), HSDB (Access on June 2015)), but no other acute effects were reported. From the above, the substance was classified in Category 3 (respiratory tract irritation). |
FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
9 | Specific target organ toxicity - Repeated exposure | Classification not possible |
- |
- | - | As for humans, a fume fever by occupational exposure was reported. However, it is described that the exposure assessment in this plant was insufficient for assessing it is due to the effects to this substance alone. (ACGIH (7th, 2003)) There is no useful information on experimental animals. Therefore, the substance was classified as "Classification not possible." |
FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
10 | Aspiration hazard | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
11 | Hazardous to the aquatic environment Short term (Acute) | Classification not possible |
- |
- | - | No data. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
11 | Hazardous to the aquatic environment Long term (Chronic) | Classification not possible |
- |
- | - | No data. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
12 | Hazardous to the ozone layer | Classification not possible |
- |
- | - | No data. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
|