Item Information
CAS RN 141-10-6
Chemical Name Pseudoionone
Substance ID m-nite-141-10-6_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) To Workplace Safety Site (MHLW)
Sample SDS by MHLW (External link) To Workplace Safety Site (MHLW)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified (Not applicable)
-
-
- - There are no chemical groups associated with explosive properties present in the molecule. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
2 Flammable gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
3 Aerosols Not classified (Not applicable)
-
-
- - Not aerosol products. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
4 Oxidizing gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
5 Gases under pressure Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
6 Flammable liquids Not classified
-
-
- - From data: a flash point of 103 deg C (test method: unknown) (IUCLID (2000)), it is estimated that it will also be above 93 deg C in the prescribed closed-cup method, therefore it was classified as "Not classified." FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
7 Flammable solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
8 Self-reactive substances and mixtures Classification not possible
-
-
- - Therer is a chemical group associated with self-reactive properties (unsaturated bond) in the molecule, but the classification is not possible due to no data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
9 Pyrophoric liquids Not classified
-
-
- - It is estimated that it does not ignite at normal temperatures from an autoignition temperature of 245 deg C (IUCLID (2000)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
10 Pyrophoric solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
11 Self-heating substances and mixtures Classification not possible
-
-
- - Test methods applicable to liquid substances are not available. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - The chemical structure of the substance does not contain metals or metalloids (B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
13 Oxidizing liquids Not classified (Not applicable)
-
-
- - The substance is an organic compound containing oxygen (but not fluorine or chlorine) which is chemically bonded only to carbon or hydrogen. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
14 Oxidizing solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
15 Organic peroxides Not classified (Not applicable)
-
-
- - Organic compounds containing no bivalent -O-O- structure in the molecule. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
16 Corrosive to metals Classification not possible
-
-
- - No data available. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Not classified
-
-
- - It was classified as "Not classified" based on a report on LD50 values of > 2,000 mg/kg, > 5,000 mg/kg, and > 8,000 mg/kg for rats (SIDS (2006)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Dermal) Not classified
-
-
- - It was classified as "Not classified" based on a report on an LD50 value of > 5,000 mg/kg for rabbits (SIDS (2006)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Inhalation: Vapours) Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Inhalation: Dusts and mists) Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
2 Skin corrosion/irritation Category 2


Warning
H315 P302+P352
P332+P313
P362+P364
P264
P280
P321
It is reported in SIDS (2006) that in a skin irritation test with rabbits according to OECD TG 404, a skin irritation score after 72 hours was 2.9, and among erythema and edema that were observed, erythema disappeared within 15 days. Other than this, it is reported that in a sensitization test with guinea pigs according to OECD TG 406, irritation by this substance markedly occurred. Besides, it is reported that in a maximization test (concentration in petrolatum: 8%) in 108 volunteers, there was no irritation. Among the above information, based on the test according to TG 404, it was classified in Category 2. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
3 Serious eye damage/eye irritation Category 2B
-
Warning
H320 P305+P351+P338
P337+P313
P264
In two eye irritation tests (OECD TG 405) with rabbits, it was assessed to be slightly irritating (SIDS (2006)). In one test of them, corneal opacity, iritis, conjunctival redness, and chemosis were observed as findings, the average scores on day 1 were 1 or higher for corneal opacity and 2 or higher for conjunctival redness, and most findings disappeared within eight days. Therefore, it was classified in Category 2B. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
4 Respiratory sensitization Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
4 Skin sensitization Classification not possible
-
-
- - Classification not possible due to lack of data. Besides, it is reported in SIDS (2006) that in a test with guinea pigs (OECD TG 406), there was no skin sensitization, but in a maximization test in 108 volunteers, sensitization was observed in eight persons. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
5 Germ cell mutagenicity Classification not possible
-
-
- - Classification not possible due to lack of data. As for in vivo, it was negative in a micronucleus test with mouse bone marrow cells (SIDS (2006)). As for in vitro, it was negative in a bacterial reverse mutation test (SIDS (2006)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
6 Carcinogenicity Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
7 Reproductive toxicity Category 2


Warning
H361 P308+P313
P201
P202
P280
P405
P501
As for fertility, in a one-generation reproductive toxicity test with rats in the oral route, reproductive toxicity (increased mortality of offspring on postnatal days 1-4) was observed at the dose where maternal toxicity (salivation, increased kidney and liver weights) was seen. As for developmental toxicity, no developmental toxicity was observed in the one-generation reproductive toxicity test with rats in the oral route and a developmental toxicity test with hamsters in the oral route (SIDS (2006)). Therefore, it was classified in Category 2. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
8 Specific target organ toxicity - Single exposure Classification not possible
-
-
- - Classification not possible due to lack of data. Besides, it is reported that no adverse effects were observed after oral administration to rats at the dose (2,000 mg/kg) within the guidance value range (SIDS (2006)). Therefore, it is thought to correspond to "Not classified" in the oral route. However, because of no toxicity information on the other routes, it was classified as "Classification not possible" due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - In a 28-day gavage administration test with rats, increased ALT activity was observed in males at the dose (converted guidance value: 77.8 mg/kg/day) within the guidance value range for Category 1-2, but no pathological changes were found in the liver (SIDS (2006)). Therefore, it corresponds to "Not classified" in the oral route. However, because of no toxicity information on the other routes, it was classified as "Classification not possible" due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
10 Aspiration hazard Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Category 2
-
-
H401 P273
P501
From 72-hour ErC50 = 2.02 mg/L for algae (Desmodesmus subspicatus) (SIDS, 2006), it was classified in Category 2. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
11 Hazardous to the aquatic environment Long term (Chronic) Category 2


-
H411 P273
P391
P501
Reliable chronic toxicity data were not obtained. Because it is not rapidly degradable (BIOWIN), and it was classified in Category 1 in acute toxicity, it was classified in Category 2. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
12 Hazardous to the ozone layer Classification not possible
-
-
- - This substance is not listed in the Annexes to the Montreal Protocol. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information