Latest GHS Classification Results by the Japanese Government (edited by NITE)

Japanese



GENERAL INFORMATION
 
Item Information
CAS RN 16949-65-8
Chemical Name Magnesium hexafluorosilicate
Substance ID m-nite-16949-65-8_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) MHLW Website (in Japanese Only)
Sample SDS by MHLW (External link) MHLW Website (in Japanese Only)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified (Not applicable)
-
-
- - There are no chemical groups associated with explosive properties present in the molecule. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
2 Flammable gases Not classified (Not applicable)
-
-
- - "Solids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
3 Aerosols Not classified (Not applicable)
-
-
- - Not an aerosol product. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Oxidizing gases Not classified (Not applicable)
-
-
- - "Solids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
5 Gases under pressure Not classified (Not applicable)
-
-
- - "Solids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
6 Flammable liquids Not classified (Not applicable)
-
-
- - "Solids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
7 Flammable solids Not classified
-
-
- - From the information as "Flammability:nicht anwendbar" (IUCLID (2000)), it was classified as "Not classified." FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
8 Self-reactive substances and mixtures Not classified (Not applicable)
-
-
- - There are no chemical groups present in the molecule associated with explosive or self-reactive properties. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
9 Pyrophoric liquids Not classified (Not applicable)
-
-
- - "Solids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
10 Pyrophoric solids Not classified
-
-
- - From the information as "Auto Flammability: nicht anwendbar" (IUCLID (2000)), it was classified as "Not classified." FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
11 Self-heating substances and mixtures Not classified
-
-
- - From the information as "Auto Flammability: nicht anwendbar" (IUCLID (2000)), it was classified as "Not classified." FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified
-
-
- - Although it contains a metal (Mg) and a semimetal (Si), from the information that water solubility is 23 g/100 g at 20 degrees C (Ullmanns (E) (6th, 2003)), it was judged to be stable in the water. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
13 Oxidizing liquids Not classified (Not applicable)
-
-
- - "Solids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
14 Oxidizing solids Classification not possible
-
-
- - An inorganic compound that contains fluorine, but the classification is not possible due to no data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
15 Organic peroxides Not classified (Not applicable)
-
-
- - It is an inorganic compound. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
16 Corrosive to metals Classification not possible
-
-
- - No established test method suitable for solid substances. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Category 3


Danger
H301 P301+P310
P264
P270
P321
P330
P405
P501
On the basis of an LD50 value of 290 mg/kg bw for rats (IUCLID (2000)), it was classified in Category 3. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Dermal) Not classified
-
-
- - On the basis of an LD50 value of >2000 mg/kg bw for rats (IUCLID (2000)), it was classified as "Not classified" in JIS classification (Category 5 or "Not classified" in UN GHS classification). FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - "Solids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Vapours) Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Dusts and mists) Category 4


Warning
H332 P304+P340
P261
P271
P312
On the basis of an LC50 valuse of 3.6 mg/L/4h for rats (IUCLID (2000)), it was classified in Category 4.
Besides, due to a melting point of 100 degrees C and no vapour pressure data, it was considered as a test by an exposure of dust.
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
2 Skin corrosion/irritation Not classified
-
-
- - From a result as "not irritating" in a test in which an 80 % aqueous solution was applied to rabbis (IUCLID (2000)), and from a report on an application of a 35% inclusion to guinea pig, rat, and miniature pig skins for 1 second to 1 hour, by which injuries were not observed (IUCLID (2000)), it was classified as "Not classified." FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
3 Serious eye damage/eye irritation Category 2


Warning
H319 P305+P351+P338
P337+P313
P264
P280
From "irritating" in a report on a test using rabbits (IUCLID (2000)), it was classified in Category 2. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Respiratory sensitization Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Skin sensitization Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
5 Germ cell mutagenicity Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
6 Carcinogenicity Classification not possible
-
-
- - No data.
Besides, it is classified in A4 in fluorides in ACGIH carcinogenicity assessment (ACGIH (2001)).
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
7 Reproductive toxicity Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
8 Specific target organ toxicity - Single exposure Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
9 Specific target organ toxicity - Repeated exposure Category 2 (teeth, bone)


Warning
H373 P260
P314
P501
In a 4-week diet administration test in rats, effects on teeth such as decoloration, lack of smoothness, a developmental disorder, a mineralization disorder, and enamel hypoplasia were observed at doses of 900 ppm (converted to 90-day equivalent quantity: 27.7 mg/kg/day) and more in macroscopy and microscopy.
In addition, the mineralization disorder in bone tissue was also found at a dose of 3000 ppm (converted to 90-day equivalent quantity: 92.3 mg/kg/day) (IUCLID (2000)).
Because the doses of the above effects correspond to Category 2 of a range of guidance values, it was classified in Category 2 (tooth, bone).
Besides, a reported NOAEL is 300 ppm (converted to 90-day equivalent quantity: 9.2 mg/kg/day).
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
10 Aspiration hazard Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Category 3
-
-
H402 P273
P501
From 96-hour LC50 = 65 mg/L for fish (Lepomis macrochirus) (IUCLID, 2000), it was classified in Category 3. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
11 Hazardous to the aquatic environment Long term (Chronic) Category 3
-
-
H412 P273
P501
Reliable chronic toxicity data are not obtained.
Due to no obtaining data on rapid degradability and acute toxicity Category 3, it was classified in Category 3.
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
12 Hazardous to the ozone layer Classification not possible
-
-
- - This substance is not listed in Annexes to the Montreal Protocol. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information