Latest GHS Classification Results by the Japanese Government (edited by NITE)

Japanese



GENERAL INFORMATION
 
Item Information
CAS RN 1854-26-8
Chemical Name 4,5-Dihydroxy-1,3-bis(hydroxymethyl)imidazolidin-2-one
Substance ID m-nite-1854-26-8_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) To Workplace Safety Site (MHLW)
Sample SDS by MHLW (External link) To Workplace Safety Site (MHLW)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified (Not applicable)
-
-
- - There is a chemical group associated with explosive properties (neighboring nitrogen atoms) in the molecule, but the classification is not possible due to no data. Besides, since it is used as a pesticide (miticide), there is no use as an explosive. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
2 Flammable gases Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
3 Aerosols Not classified (Not applicable)
-
-
- - Not aerosol products. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
4 Oxidizing gases Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
5 Gases under pressure Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
6 Flammable liquids Not classified
-
-
- - Solid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
7 Flammable solids Not classified (Not applicable)
-
-
- - No data available. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
8 Self-reactive substances and mixtures Not classified (Not applicable)
-
-
- - There is a chemical group associated with explosive properties (neighboring nitrogen atoms) in the molecule, but the classification is not possible due to no data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
9 Pyrophoric liquids Not classified
-
-
- - Solid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
10 Pyrophoric solids Not classified (Not applicable)
-
-
- - No data available. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
11 Self-heating substances and mixtures Classification not possible
-
-
- - No data available. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - The chemical structure of the substance does not contain metals or metalloids (B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
13 Oxidizing liquids Classification not possible
-
-
- - Solid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
14 Oxidizing solids Not classified (Not applicable)
-
-
- - The substance is an organic compound containing chlorine (but not fluorine or oxygen) which is chemically bonded only to carbon or hydrogen. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
15 Organic peroxides Not classified (Not applicable)
-
-
- - Organic compounds containing no bivalent -O-O- structure in the molecule. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
16 Corrosive to metals Classification not possible
-
-
- - Test methods applicable to solid substances are not available. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Not classified
-
-
- - It was classified as "Not classified" based on a report on LD50 values of > 2,880 mg/kg and 10,000 mg/kg for rats (SIDS (2002)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Dermal) Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Inhalation: Vapours) Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Inhalation: Dusts and mists) Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
2 Skin corrosion/irritation Not classified
-
-
- - It was classified as "Not classified" because it is reported that no irritation was seen in a test with rabbits (SIDS (2002), IUCLID (2000)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
3 Serious eye damage/eye irritation Not classified
-
-
- - It was classified as "Not classified" because it is described in SIDS (2002) that this substance does not cause primary irritation, and two tests are reported in IUCLID (2000), which resulted in slight or no irritation. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
4 Respiratory sensitization Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
4 Skin sensitization Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
5 Germ cell mutagenicity Classification not possible
-
-
- - Classification not possible due to lack of data. As for in vivo, it was negative in a micronucleus test with mouse bone marrow cells. As for in vitro, there is one weakly positive result in a bacterial reverse mutation test, but it was negative in all of the other reverse mutation tests. Thre are no other in vitro test data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
6 Carcinogenicity Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
7 Reproductive toxicity Classification not possible
-
-
- - Classification not possible due to lack of data. Besides, no developmental toxicity was observed in a developmental toxicity test with rats in the oral route (gavage) (SIDS (2002)). No reports on fertility were obtained. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
8 Specific target organ toxicity - Single exposure Category 3 (Respiratory tract irritation)


Warning
H335 P304+P340
P403+P233
P261
P271
P312
P405
P501
It was classified in Category 3 (respiratory tract irritation) because it is reported that dyspnea and irritation of mucous membranes were observed in rats exposed by inhalation (corresponding to the saturated vapour) at room temperatures (SIDS (2002)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - In 90-day gavage administration tests with rats and mice, no toxicity findings were observed even at the high doses of 1,000 mg/kg/day or above (SIDS (2002), IUCLID (2000)). Therefore, it corresponds to "Not classified" in the oral route. However, because of no toxicity information on the other routes, it was classified as "Classification not possible" due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
10 Aspiration hazard Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Category 3
-
-
H402 P273
P501
From 72-hour EC50 = 14.76 mg/L (converted value) for algae (Desmodesmus subspicatus) (SIDS, 2002), it was classified in Category 3. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
11 Hazardous to the aquatic environment Long term (Chronic) Not classified
-
-
- - If chronic toxicity data are used, appropriate data on rapid degradability were not obtained, and it is judged to be not rapidly degradable (SIDS, 2002), then it is classified as "Not classified" due to 72-hour NOEC = 6 mg/L (converted value) for algae (Desmodesmus subspicatus) (SIDS, 2002).
If acute toxicity data are used for a trophic level for which chronic toxicity data are not obtained, then it is classified as "Not classified" due to being not rapidly degradable (SIDS, 2002), and 96-hour LC50 = 880 mg/L (converted value) for fish (Pimephales promelas) (SIDS, 2002).
From the above results, it was classified as "Not classified."
FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
12 Hazardous to the ozone layer Classification not possible
-
-
- - This substance is not listed in the Annexes to the Montreal Protocol. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information