Latest GHS Classification Results by the Japanese Government (edited by NITE)

Japanese



GENERAL INFORMATION
 
Item Information
CAS RN 286-20-4
Chemical Name Cyclohexene oxide
Substance ID m-nite-286-20-4_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) To Workplace Safety Site (MHLW)
Sample SDS by MHLW (External link) To Workplace Safety Site (MHLW)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified (Not applicable)
-
-
- - There are no chemical groups associated with explosive properties present in the molecule. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
2 Flammable gases Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
3 Aerosols Not classified (Not applicable)
-
-
- - Not an aerosol product. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Oxidizing gases Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
5 Gases under pressure Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
6 Flammable liquids Category 3


Warning
H226 P303+P361+P353
P370+P378
P403+P235
P210
P233
P240
P241
P242
P243
P280
P501
A flash point of 24 degrees C [closed cup] (GESTIS (Access on Dec. 2011); MSDS (Sigma-Aldrich) (Access on Dec. 2011)), which is >= 23 degrees C and <= 60 degrees C, corresponds to Category 3. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
7 Flammable solids Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
8 Self-reactive substances and mixtures Classification not possible
-
-
- - There is a chemical group present in the molecule associated with a self-reactive property (strained ring: epoxy group), but the classification is not possible due to no data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
9 Pyrophoric liquids Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
10 Pyrophoric solids Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
11 Self-heating substances and mixtures Classification not possible
-
-
- - No established test method suitable for liquid substances. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - Not containing metals or semimetals (B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
13 Oxidizing liquids Not classified (Not applicable)
-
-
- - An organic compound does not contain fluorine or chlorine but contains oxygen which is not chemically bonded to elements other than carbon or hydrogen. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
14 Oxidizing solids Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
15 Organic peroxides Not classified (Not applicable)
-
-
- - An organic compound that does not contain -O-O- structure. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
16 Corrosive to metals Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Category 4


Warning
H302 P301+P312
P264
P270
P330
P501
From an LD50 value of 1090 micro L/kg (1053 mg/kg) for rats (RTECS (1997): original literature American Industrial Hygiene Association Journal. 30, 470, 1969) with confirmation of the description in the original literature, it was classified in Category 4. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Dermal) Category 3


Danger
H311 P302+P352
P361+P364
P280
P312
P321
P405
P501
From an LD50 value of 630 micro L/kg (609 mg/kg) for rabbits (RTECS (1997): original literature American Industrial Hygiene Association Journal. 30, 470, 1969) with confirmation of the description in the original literature, it was classified in Category 3. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - "Liquids" according to GHS definition. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Vapours) Classification not possible
-
-
- - Because the category cannot be determined from LCLo of 2000 ppm/4h for rats in a 4-hour exposure (RTECS (1997): original literature American Industrial Hygiene Association Journal. 30, 470, 1969), the classification is not possible.
Besides, a reference value of gasses as a vapour with hardly included mist was applied because the test concentration (2000 ppm) is lower than 90 % of the saturated vapour pressure concentration (15132 ppm).
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
1 Acute toxicity (Inhalation: Dusts and mists) Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
2 Skin corrosion/irritation Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
3 Serious eye damage/eye irritation Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Respiratory sensitization Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
4 Skin sensitization Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
5 Germ cell mutagenicity Not classified
-
-
- - On the basis that a micronucleus test using bone marrow after intraperitoneal administration in rats (in vivo somatic cell mutagenicity test) reported a negative (NTP DB (Access on Dec. 2011)), it was classified as "Not classified."
Besides, an Ames test reported mostly a positive result as an in vitro test (NTP DB (Access on Dec. 2011)).
FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
6 Carcinogenicity Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
7 Reproductive toxicity Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
8 Specific target organ toxicity - Single exposure Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
10 Aspiration hazard Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
11 Hazardous to the aquatic environment Long term (Chronic) Classification not possible
-
-
- - No data. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)
12 Hazardous to the ozone layer Classification not possible
-
-
- - This substance is not listed in Annexes to the Montreal Protocol. FY2011 GHS Classification Guidance by the Japanese Government (July, 2010)


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information