Item | Information |
---|---|
CAS RN | 431-89-0 |
Chemical Name | 1,1,1,2,3,3,3-Heptafluoropropane |
Substance ID | m-nite-431-89-0_v1 |
Download of Excel format | Excel file |
Item | Information |
---|---|
Guidance used for the classification (External link) | To Guidance List |
UN GHS document (External link) | To UN GHS document |
FAQ(GHS classification results by the Japanese Government) | To FAQ |
List of Information Sources (Excel file) | List of Information Sources |
List of Definitions/Abbreviations | Definitions/Abbreviations |
Sample Label by MHLW (External link) | To Workplace Safety Site (MHLW) |
Sample SDS by MHLW (External link) | To Workplace Safety Site (MHLW) |
OECD/eChemPortal (External link) | To OECD/eChemPortal (External link) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Explosives | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
2 | Flammable gases | Not classified |
- |
- | - | Not combustible gas (IMDG (2006)) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
3 | Aerosols | Not classified (Not applicable) |
- |
- | - | Not aerosol products. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
4 | Oxidizing gases | Classification not possible |
- |
- | - | No data available. The substance is classified into Division 2.2 in UNRTDG (UN3296) and Subsidiary risk is not 5.1. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
5 | Gases under pressure | Low pressure liquefied gas |
Warning |
H280 | P410+P403 | Critical temperature is 101.8 degC (Ullmanns (E) (2003)) exceeding 65 degC. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
6 | Flammable liquids | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
7 | Flammable solids | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
8 | Self-reactive substances and mixtures | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
9 | Pyrophoric liquids | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
10 | Pyrophoric solids | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
11 | Self-heating substances and mixtures | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
12 | Substances and mixtures which, in contact with water, emit flammable gases | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
13 | Oxidizing liquids | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
14 | Oxidizing solids | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
15 | Organic peroxides | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
16 | Corrosive to metals | Classification not possible |
- |
- | - | Test methods applicable to gaseous substances are not available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
17 | Desensitized explosives | - |
- |
- | - | - | - | - |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Acute toxicity (Oral) | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
1 | Acute toxicity (Dermal) | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
1 | Acute toxicity (Inhalation: Gases) | Not classified |
- |
- | - | Based on no mortality in rats exposed at 800,000 ppm for 4-hour (PATTY (5th, 2001)), the substance was classified as "Not classified". | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
1 | Acute toxicity (Inhalation: Vapours) | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
1 | Acute toxicity (Inhalation: Dusts and mists) | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
2 | Skin corrosion/irritation | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
3 | Serious eye damage/eye irritation | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
4 | Respiratory sensitization | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
4 | Skin sensitization | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
5 | Germ cell mutagenicity | Not classified |
- |
- | - | Based on a negative result in an inhalation mouse bone marrow micronucleus test (in vivo somatic cell mutagenicity tests) (PATTY (5th, 2001)), the substance was classified as "Not classified". As relevant information, from in vitro mutagenicity tests, there are reports of a negative bacteria reverse mutation test using S. typhimurium and forward mutation test using mouse lymphoma cells (PATTY (5th, 2001)). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
6 | Carcinogenicity | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
7 | Reproductive toxicity | Classification not possible |
- |
- | - | Although there is a report that no evidence of parental general effects, fetal toxicity, developmental effects or teratogenicity was observed in a rat developmental test by inhalation during organogenesis period (PATTY (5th, 2001)), classification was not possible due to lack of data for effects on sexual function and fertility of parental animals. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
8 | Specific target organ toxicity - Single exposure | Classification not possible |
- |
- | - | Classification not possible due to lack of data. As relevant information, there are reports that no deaths occurred when rats were exposed by inhalation to 800,000 ppm for 4-hour (no report for symptoms) (PATTY (5th, 2001)) and that exposure of 4 male and 4 female volunteers at dose levels of 1000 - 8000 ppm for 1-hour resulted in no adverse symptoms or changes in pulse, blood pressure or heart rhythm (PATTY (5th, 2001)). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
9 | Specific target organ toxicity - Repeated exposure | Not classified |
- |
- | - | It was reported that in a 4-week inhalation exposure (6h/day) test with rats resulted in no notable toxic signs at dose levels of up to 50,000 ppm (90-day equivalence: 15,385 ppm) and that no adverse effects were observed at dose levels of up to 105,000 ppm (90-day equivalence: 32,300 ppm) (PATTY (5th, 2001)). Since the substance is a gas and the exposure levels exceed the guidance value range for Category 2, it was classified as "Not classified" based on data from inhalation exposure only. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
10 | Aspiration hazard | Not classified (Not applicable) |
- |
- | - | Gas (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
11 | Hazardous to the aquatic environment Short term (Acute) | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
11 | Hazardous to the aquatic environment Long term (Chronic) | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
12 | Hazardous to the ozone layer | - |
- |
- | - | - | - | - |
|