Latest GHS Classification Results by the Japanese Government (edited by NITE)

Japanese



GENERAL INFORMATION
 
Item Information
CAS RN 485-31-4
Chemical Name binapacryl
Substance ID m-nite-485-31-4_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) To Workplace Safety Site (MHLW)
Sample SDS by MHLW (External link) To Workplace Safety Site (MHLW)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified
-
-
- - Not classified because of no appropriate data found on the explosibility, though the substance contains N-O bonds as chemical groups associated with explosive properties present and has its oxygen balance calculated at -163.8, higher than -200 of the criteria. FY2006 GHS Classification Manual (10 Feb, 2006)
2 Flammable gases Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
3 Aerosols Not classified (Not applicable)
-
-
- - Not aerosol products FY2006 GHS Classification Manual (10 Feb, 2006)
4 Oxidizing gases Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
5 Gases under pressure Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
6 Flammable liquids Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
7 Flammable solids Classification not possible
-
-
- - Although it is combustible (ICSC (J) 1997), there is no UNRTDG No., and test data is not found either. So it cannot be classified as data is insufficient,. FY2006 GHS Classification Manual (10 Feb, 2006)
8 Self-reactive substances and mixtures Not classified
-
-
- - Although the grouping relevant to explosive (N-O) was included, the grouping relevant to autoreactive was not included and the data in which autoreactive is indicated was not found, either. So it was considered outside of Category. FY2006 GHS Classification Manual (10 Feb, 2006)
9 Pyrophoric liquids Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
10 Pyrophoric solids Not classified
-
-
- - Non-pyrophoric when in contact with air at a room temperature and used as agricultural chemicals. FY2006 GHS Classification Manual (10 Feb, 2006)
11 Self-heating substances and mixtures Classification not possible
-
-
- - Test methods applicable to solid (melting point <= 140degC) substances are not available. FY2006 GHS Classification Manual (10 Feb, 2006)
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - The chemical structure of the substance does not contain metals or metaloids(B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). FY2006 GHS Classification Manual (10 Feb, 2006)
13 Oxidizing liquids Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
14 Oxidizing solids Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
15 Organic peroxides Not classified (Not applicable)
-
-
- - Organic compounds containing no -0-0- structure FY2006 GHS Classification Manual (10 Feb, 2006)
16 Corrosive to metals Classification not possible
-
-
- - Test methods applicable to solid substances are not available. FY2006 GHS Classification Manual (10 Feb, 2006)
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Category 3


Danger
H301 P301+P310
P264
P270
P321
P330
P405
P501
Because the oral LD50 value in rats was 58mg/kg (RTECS (1996), HSDB (2003)), the substance was classified as Category 3.

[Note] Also refer to the toxicity information for dinoseb (ID 0321, CAS number: 88-85-7) and dinoseb acetate (ID 1239, CAS number: 2813-95-8), which have the same basic skeleton.
FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Dermal) Category 3


Danger
H311 P302+P352
P361+P364
P280
P312
P321
P405
P501
Rat dermal LD50 = 720mg/kg (RTECS (1996)). Rabbit dermal LD50 = 750mg/kg (RTECS (1996), HSDB (2003)). The higher toxic value (LD50 = 720mg/kg) was adopted , and it was set to as Category 3. FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - Solid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Inhalation: Vapours) Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Inhalation: Dusts and mists) Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
2 Skin corrosion/irritation Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
3 Serious eye damage/eye irritation Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
4 Respiratory sensitization Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
4 Skin sensitization Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
5 Germ cell mutagenicity Classification not possible
-
-
- - Insufficient data available FY2006 GHS Classification Manual (10 Feb, 2006)
6 Carcinogenicity Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
7 Reproductive toxicity Classification not possible
-
-
- - Since data is insufficient. In addition, "this product is dimethyl acrylate ester of JINOZEBU, is metabolized and generates JINOZEBU. Toxicity is based on JINOZEBU (ICSC (J) (1997)", so refer to 2-(1-methylpropyl)-4,6-dinitrophenol (ID 0321, CAS number: 88-85-7). FY2006 GHS Classification Manual (10 Feb, 2006)
8 Specific target organ toxicity - Single exposure Classification not possible
-
-
- - Insufficient data available. FY2006 GHS Classification Manual (10 Feb, 2006)
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - Insufficient data available FY2006 GHS Classification Manual (10 Feb, 2006)
10 Aspiration hazard Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Category 1


Warning
H400 P273
P391
P501
It was classified into Category 1 from 96-hour LC50=15microg/L of fishes (American catfish), and others (HSDB, 2004). FY2006 GHS Classification Manual (10 Feb, 2006)
11 Hazardous to the aquatic environment Long term (Chronic) Category 1


Warning
H410 P273
P391
P501
Classified into Category 1, since acute toxicity is Category 1, supposed not rapidly degrading (BIOWIN), and bioaccumulative (log Kow=4.49 (PHYSPROP Database, 2005)). FY2006 GHS Classification Manual (10 Feb, 2006)
12 Hazardous to the ozone layer -
-
-
- - - - -


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information