PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified (Not applicable)
-
-
- - There are no chemical groups associated with explosive properties present in the molecule. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
2 Flammable gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
3 Aerosols Not classified (Not applicable)
-
-
- - Not aerosol products. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
4 Oxidizing gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
5 Gases under pressure Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
6 Flammable liquids Category 2


Danger
H225 P303+P361+P353
P370+P378
P403+P235
P210
P233
P240
P241
P242
P243
P280
P501
It was classified in Category 2 from a flash point of -29 deg C (closed-cup) (HSDB (Access on December (2013))) and a boiling point of 42 deg C (ICSC (2008)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
7 Flammable solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
8 Self-reactive substances and mixtures Classification not possible
-
-
- - There is a chemical group associated with self-reactive properties (unsaturated bond) present in the molecule, but the classification is not possible due to no data. Besides, the one which is added a stabilizer, BHT (SIDS (2002)) is defined as Type G. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
9 Pyrophoric liquids Classification not possible
-
-
- - No data available. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
10 Pyrophoric solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
11 Self-heating substances and mixtures Classification not possible
-
-
- - Test methods applicable to liquid substances are not available. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - The chemical structure of the substance does not contain metals or metalloids (B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
13 Oxidizing liquids Not classified (Not applicable)
-
-
- - Organic compounds containing no oxygen, fluorine or chlorine. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
14 Oxidizing solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
15 Organic peroxides Not classified (Not applicable)
-
-
- - Organic compounds containing no bivalent -O-O- structure in the molecule. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
16 Corrosive to metals Classification not possible
-
-
- - Test methods applicable to low-temperature-boiling liquids are not available. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Not classified
-
-
- - It was classified as "Not classified" (Category 5 in UN GHS classification) because it is described in SIDS (2002) that an LD50 value was < 5,000 mg/kg for rats (OECD TG 401), but from > 1,000 mg/kg of a preliminary test result, an LD50 value was estimated to be > 2,000 mg/kg. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Dermal) Not classified
-
-
- - It was classified as "Not classified" based on a report on an LD50 value of > 3,200 mg/kg for rabbits (OECD TG 402) (SIDS (2002)). Besides, no death was observed after the application of 3,200 mg/kg (SIDS (2002)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Inhalation: Vapours) Not classified
-
-
- - It was classified as "Not classified" based on a report on an LC50 value (4 hours) of > 20,917 ppm (= 58.2 mg/L) for rats (OECD TG 403) (SIDS (2002)). Besides, because the test concentration (20,917 ppm) was lower than 90% of the saturated vapour pressure concentration (526,159 ppm), a reference value in the unit of ppm was applied as a vapour without mist. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
1 Acute toxicity (Inhalation: Dusts and mists) Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
2 Skin corrosion/irritation Classification not possible
-
-
- - Classification not possible due to lack of data. Besides, it is described in SIDS (2002) that moderate irritation was observed in an acute dermal toxicity test in which 3,200 mg/kg was applied to rabbits for 24 hours, but it was not adopted because of using a high application amount and long application time. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
3 Serious eye damage/eye irritation Classification not possible
-
-
- - Classification not possible due to lack of data. Besides, it is described in SIDS (2002) that this substance is not expected to be a severe eye irritant from data on related compounds. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
4 Respiratory sensitization Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
4 Skin sensitization Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
5 Germ cell mutagenicity Classification not possible
-
-
- - It was classified as "Classification not possible" because it was not possible to classify a substance as "Not classified" according to the revised GHS classification guidance for the Japanese government. As for in vivo, it was negative in micronucleus tests with bone marrow cells of mice and rats (SIDS (2002)), and as for in vitro, it was negative in a bacterial reverse mutation test, a mouse lymphoma test and a chromosomal aberration test with cultured mammalian cells (SIDS (2002), IUCLID (2000)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
6 Carcinogenicity Classification not possible
-
-
- - Classification not possible due to lack of data. Besides, isoprene, the isomer, was not carcinogenic at doses up to 7,000 ppm in an inhalation administration test with rats (SIDS (2002)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
7 Reproductive toxicity Classification not possible
-
-
- - Classification not possible due to lack of data. Besides, it is reported in a combined repeated dose toxicity study with the reproduction/developmental toxicity screening test with rats (OECD TG 422), no evidence of reproductive toxicity in parent animals was found, and there were almost no exposure effects on the development of offspring (SIDS (2002), IUCLID (2000)). However, because the test is a screening test, and there was no sufficient information on developmental toxicity, it was classified as "Classification not possible." FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
8 Specific target organ toxicity - Single exposure Category 3 (Respiratory tract irritation)


Warning
H335 P304+P340
P403+P233
P261
P271
P312
P405
P501
It was classified in Category 3 (respiratory tract irritation) because it is described that it is irritating to the respiratory tract in humans, and the threshold level causing hypoxia was 850-1,000 mg/m3 for this substance (IUCLID (2000)). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - It is described that in a combined repeated dose toxicity study with the reproduction/developmental toxicity screening test with rats, no toxicity effects were observed even after the oral administration of a limit dose (1,000 mg/kg/day) (SIDS (2002)), therefore it corresponds to "Not classified" in the oral route. However, because of no toxicity information on the other routes, the classification is not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
10 Aspiration hazard Classification not possible
-
-
- - Classification not possible due to lack of data. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Not classified
-
-
- - It was classified as "Not classified" froom 96-hour ErC50 = 174.6 mg/L for algae (Pseudokirchneriella subcapitata), 48-hour EC50 = 221.5 mg/L for crustacea (Daphnia magna), and 96-hour LC50 = 139.9 mg/L for fish (Pimephales promelas) (all SIDS, 2002). FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
11 Hazardous to the aquatic environment Long term (Chronic) Not classified
-
-
- - Reliable chronic toxicity data were not obtained. It was classified as "Not classified" because it is not water-insoluble (water solubility = 0.069 g/100 mL, ICSC, 2008), and it was classified as "Not classified" in acute toxicity. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))
12 Hazardous to the ozone layer Classification not possible
-
-
- - This substance is not listed in the Annexes to the Montreal Protocol. FY2013 GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.0))


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information