Item | Information |
---|---|
CAS RN | 506-93-4 |
Chemical Name | Guanidinium nitrate |
Substance ID | m-nite-506-93-4_v1 |
Download of Excel format | Excel file |
Item | Information |
---|---|
Guidance used for the classification (External link) | To Guidance List |
UN GHS document (External link) | To UN GHS document |
FAQ(GHS classification results by the Japanese Government) | To FAQ |
List of Information Sources (Excel file) | List of Information Sources |
List of Definitions/Abbreviations | Definitions/Abbreviations |
Sample Label by MHLW (External link) | To Workplace Safety Site (MHLW) |
Sample SDS by MHLW (External link) | To Workplace Safety Site (MHLW) |
OECD/eChemPortal (External link) | To OECD/eChemPortal (External link) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Explosives | Not classified |
- |
- | - | Classified into Not classified since the substance is classified into Division 5.1, PG III in UNRTDG (UN1467) though it contains chemical groups (nitrates) associated with explosive properties present in the molecules. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
2 | Flammable gases | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
3 | Aerosols | Not classified (Not applicable) |
- |
- | - | Not aerosol products. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
4 | Oxidizing gases | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
5 | Gases under pressure | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
6 | Flammable liquids | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
7 | Flammable solids | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
8 | Self-reactive substances and mixtures | Not classified (Not applicable) |
- |
- | - | The substance is classified as Oxidizing agents. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
9 | Pyrophoric liquids | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
10 | Pyrophoric solids | Not classified |
- |
- | - | The substance does not fall into upper Division 4.2, PG I since it is classified into Division 5.1 (Oxidizing substances), PG III in UNRTDG (UN1467). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
11 | Self-heating substances and mixtures | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
12 | Substances and mixtures which, in contact with water, emit flammable gases | Not classified (Not applicable) |
- |
- | - | The chemical structure of the substance does not contain metals or metalloids (B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
13 | Oxidizing liquids | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
14 | Oxidizing solids | Category 3 |
Warning |
H272 | P370+P378 P210 P220 P280 P501 |
The substance is solid which is classified into Division 5.1, PG III in UNRTDG (UN1467). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
15 | Organic peroxides | Not classified (Not applicable) |
- |
- | - | Organic compounds containing no bivalent -O-O- structure | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
16 | Corrosive to metals | Classification not possible |
- |
- | - | Test methods applicable to solid substances are not available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
17 | Desensitized explosives | - |
- |
- | - | - | - | - |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Acute toxicity (Oral) | Category 4 |
Warning |
H302 | P301+P312 P264 P270 P330 P501 |
LD50 values of 1260 mg/kg bw, 989.6 mg/kg bw and 729.8 mg/kg bw for rats (IUCLID (2000)) correspond to Category 4. The substance was classified into Category 4. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
1 | Acute toxicity (Dermal) | Not classified |
- |
- | - | Based on a LD0 value of >2000 mg/kg for rabbits (IUCLID (2000)), the substance was classified as "Not classified" in JIS Classification (correspond to Category 5 or "Not classified" in GHS classification). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
1 | Acute toxicity (Inhalation: Gases) | Not classified (Not applicable) |
- |
- | - | Solid (GHS definition) | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
1 | Acute toxicity (Inhalation: Vapours) | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
1 | Acute toxicity (Inhalation: Dusts and mists) | Classification not possible |
- |
- | - | Classification not possible due to lack of data. As relevant information, a LC0 value was >0.853 mg/L/4h for rats (IUCLID (2000)). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
2 | Skin corrosion/irritation | Not classified |
- |
- | - | Based on a result of "slight irritating "in a skin irritation test with rabbits (OECD TG404 (GLP)) where slight erythema and edema in 1/3 animals at 1-hour after application of 500 mg to the skin for 4-hour (HSDB (2008)), the substance was classified as "Not classified". As relevant information, there are reports of "highly irritating" in another rabbit test (EPA Guideline (GLP)) where 500 mg was applied to the skin for 24-hour (HSDB (2008)) and "slightly irritating" in a 24-hour application test (EPA Guideline (GLP)) (IUCLID (2000)). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
3 | Serious eye damage/eye irritation | Category 2A |
Warning |
H319 | P305+P351+P338 P337+P313 P264 P280 |
In a Draize test using 6 rabbits (EPA Guideline (GLP)), conjunctival swelling and cloudy cornea were observed in at least 1 animal at periods up to 21 days and also iritis was observed at 72-hour and 14 days. Based on the rating of irritating (HSDB (2008)), the substance was classified into Category 2A. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
4 | Respiratory sensitization | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
4 | Skin sensitization | Classification not possible |
- |
- | - | Although there is a report of "not sensitizing" in a guinea pig Buehler test (EPA Guideline (GLP)) (IUCLID (2000)), classification was not possible since this information is reported in a document in List 2 and the positive ratio is not clear. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
5 | Germ cell mutagenicity | Classification not possible |
- |
- | - | Classification not possible due to lack of data from in vivo mutagenicity tests. From in vitro mutagenicity tests, there are reports of a negative Ames test and a negative CHL cell chromosomal aberration test (IUCLID (2000)). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
6 | Carcinogenicity | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
7 | Reproductive toxicity | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
8 | Specific target organ toxicity - Single exposure | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
9 | Specific target organ toxicity - Repeated exposure | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
10 | Aspiration hazard | Classification not possible |
- |
- | - | No data available. | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
11 | Hazardous to the aquatic environment Short term (Acute) | Category 3 |
- |
H402 | P273 P501 |
Classified into Category 3 from its 48h-LC50 = 23 mg/L for Crustacea (Daphnia magna) (HSDB, 2009; IUCLID, 2000). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
11 | Hazardous to the aquatic environment Long term (Chronic) | Not classified |
- |
- | - | Classified into Not classified since its 21d-NOEC = 2.9 mg/L (>1 mg/L) for Crustacea (Daphnia magna) (IUCLID, 2000) though its acute toxicity is Category 3 and it is not rapidly degradable (BIOWIN). | FY2009 | GHS Classification Guidance by the Japanese Government (March, 2009) |
12 | Hazardous to the ozone layer | - |
- |
- | - | - | - | - |
|