Latest GHS Classification Results by the Japanese Government (edited by NITE)

Japanese



GENERAL INFORMATION
Item Information
CAS RN 615-53-2
Chemical Name ethyl methylnitrosocarbamate
Substance ID m-nite-615-53-2_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) MHLW Website (in Japanese Only)
Sample SDS by MHLW (External link) MHLW Website (in Japanese Only)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Classification not possible
-
-
- - Classification not possible due to lack of data by regulated test methods, though "the substance explodes when distilling under normal pressure" (Bretherick (J), 5th, 1998). FY2006 GHS Classification Manual (10 Feb, 2006)
2 Flammable gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
3 Aerosols Not classified (Not applicable)
-
-
- - Not aerosol products FY2006 GHS Classification Manual (10 Feb, 2006)
4 Oxidizing gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
5 Gases under pressure Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
6 Flammable liquids Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
7 Flammable solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
8 Self-reactive substances and mixtures Classification not possible
-
-
- - There is information that it explodes when atmospheric distillation is carried out (Bretherick (J), (5th, 1998)), but there is no data based on a set test method. FY2006 GHS Classification Manual (10 Feb, 2006)
9 Pyrophoric liquids Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
10 Pyrophoric solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
11 Self-heating substances and mixtures Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - The chemical structure of the substance does not contain metals or metaloids(B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). FY2006 GHS Classification Manual (10 Feb, 2006)
13 Oxidizing liquids Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
14 Oxidizing solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
15 Organic peroxides Not classified (Not applicable)
-
-
- - Containing no -0-0- structure FY2006 GHS Classification Manual (10 Feb, 2006)
16 Corrosive to metals Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Category 3


Danger
H301 P301+P310
P264
P270
P321
P330
P405
P501
Category 3 based on SPECIES: Rat; Median lethal level: 238mg/kg; REFERENCE SOURCE: PATTY 4th (1994) FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Dermal) Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Inhalation: Vapours) Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Inhalation: Dusts and mists) Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
2 Skin corrosion/irritation Category 2


Warning
H315 P302+P352
P332+P313
P362+P364
P264
P280
P321
There is no concrete case report. But from description that a blister is made by contact (PATTY (4th, 1994)), it was judged that there was skin irritation, and it was set as Category 2. FY2006 GHS Classification Manual (10 Feb, 2006)
3 Serious eye damage/eye irritation Category 2A


Warning
H319 P305+P351+P338
P337+P313
P264
P280
We found no concrete case reports. However, based on the description that "the eye may be stimulated by contact with this product"(HSFS (1999)), and based on the description that "the steam of this product showed severe irritation to the eye"(PATTY (4th, 1994)). So we classified it as Category 2A-2B FY2006 GHS Classification Manual (10 Feb, 2006)
4 Respiratory sensitization Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
4 Skin sensitization Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
5 Germ cell mutagenicity Category 2


Warning
H341 P308+P313
P201
P202
P280
P405
P501
There is a positive result by the DNA damage test using a rat stomach which is an in vivo genotoxicity study using a somatic cell (RTECS, 2006), and the reverse mutation test using the bacteria which is the in vitro mutagenicity test (RTECS, 2006). So it is set as Category 2. FY2006 GHS Classification Manual (10 Feb, 2006)
6 Carcinogenicity Category 2


Warning
H351 P308+P313
P201
P202
P280
P405
P501
Since it was classified into group 2B (IARC Suppl.7, 1987) in IARC and 2B in Japan Assoc. of Industrial Health (industrial hygene academic society recommentation, 2005), it was considered as Category 2. FY2006 GHS Classification Manual (10 Feb, 2006)
7 Reproductive toxicity Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
8 Specific target organ toxicity - Single exposure Category 3 (Respiratory tract irritation)


Warning
H335 P304+P340
P403+P233
P261
P271
P312
P405
P501
Although there was no concrete case report, because of a description in PATTY (4th, 1994) referring to that respiratory tracts were stimulated intensively by vapor, it was judged as Category 3 (respiratory irritant). FY2006 GHS Classification Manual (10 Feb, 2006)
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - Classification not possible due to lack of data FY2006 GHS Classification Manual (10 Feb, 2006)
10 Aspiration hazard Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Classification not possible
-
-
- - Insufficient data available. FY2006 GHS Classification Manual (10 Feb, 2006)
11 Hazardous to the aquatic environment Long term (Chronic) Classification not possible
-
-
- - Classification not possible due to lack of data FY2006 GHS Classification Manual (10 Feb, 2006)
12 Hazardous to the ozone layer -
-
-
- - - - -


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information