Latest GHS Classification Results by the Japanese Government (edited by NITE)

Japanese



GENERAL INFORMATION
 
Item Information
CAS RN 61789-80-8
Chemical Name Bis(hydrogenated tallow)dimethylammonium chloride
Substance ID m-nite-61789-80-8_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) MHLW Website (in Japanese Only)
Sample SDS by MHLW (External link) MHLW Website (in Japanese Only)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified (Not applicable)
-
-
- - Containing no chemical groups with explosive properties FY2006 GHS Classification Manual (10 Feb, 2006)
2 Flammable gases Not classified (Not applicable)
-
-
- - Classified as "solid" according to GHS definition FY2006 GHS Classification Manual (10 Feb, 2006)
3 Aerosols Not classified (Not applicable)
-
-
- - Not aerosol products FY2006 GHS Classification Manual (10 Feb, 2006)
4 Oxidizing gases Not classified (Not applicable)
-
-
- - Classified as "solid" according to GHS definition FY2006 GHS Classification Manual (10 Feb, 2006)
5 Gases under pressure Not classified (Not applicable)
-
-
- - Classified as "solid" according to GHS definition FY2006 GHS Classification Manual (10 Feb, 2006)
6 Flammable liquids Not classified (Not applicable)
-
-
- - Classified as "solid" according to GHS definition FY2006 GHS Classification Manual (10 Feb, 2006)
7 Flammable solids Classification not possible
-
-
- - Classification not possible due to lack of data, though distearyldimethylammonium chloride (C38H80ClN), a main component of commercial products, is classified as flammable according to ICSC (2004). FY2006 GHS Classification Manual (10 Feb, 2006)
8 Self-reactive substances and mixtures Not classified (Not applicable)
-
-
- - Containing no chemical groups with explosive or self-reactive properties FY2006 GHS Classification Manual (10 Feb, 2006)
9 Pyrophoric liquids Not classified (Not applicable)
-
-
- - Classified as "solid" according to GHS definition FY2006 GHS Classification Manual (10 Feb, 2006)
10 Pyrophoric solids Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
11 Self-heating substances and mixtures Classification not possible
-
-
- - Test methods applicable to substances which begin to decompose at temperatures lower than the test temperatures are not available (distearyldimethylammonium chloride (C38H80ClN), a main component of commercial products, decomposes at 135degC, which is lower than the melting point (ICSC, 2004), test temperature: 140degC). FY2006 GHS Classification Manual (10 Feb, 2006)
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - Containing no metals or metalloids (B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At) FY2006 GHS Classification Manual (10 Feb, 2006)
13 Oxidizing liquids Not classified (Not applicable)
-
-
- - Classified as "solid" according to GHS definition FY2006 GHS Classification Manual (10 Feb, 2006)
14 Oxidizing solids Classification not possible
-
-
- - Classification not possible due to lack of data, though being organic compounds containing chlorine bound to elements other than carbon and hydrogen FY2006 GHS Classification Manual (10 Feb, 2006)
15 Organic peroxides Not classified (Not applicable)
-
-
- - Organic compounds containing no "-O-O-" structure FY2006 GHS Classification Manual (10 Feb, 2006)
16 Corrosive to metals Classification not possible
-
-
- - Test methods applicable to solid substances are not available (distearyldimethylammonium chloride (C38H80ClN), a main component of commercial products, decomposes at 135degC, which is lower than the melting point (ICSC, 2004), test temperature: 55degC). FY2006 GHS Classification Manual (10 Feb, 2006)
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Not classified
-
-
- - Based on the rat LD50 (oral route) value of 11,300mg/kg (CERI-NITE Hazard Assessment No.78 (2005)). FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Dermal) Not classified
-
-
- - Based on the rat LD50 (dermal route) value of >2,000mg/kg (CERI-NITE Hazard Assessment No.78 (2005)). FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - Due to the fact that the substance is "solid" according to the GHS definition and inhalation of its gas is not expected. FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Inhalation: Vapours) Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
1 Acute toxicity (Inhalation: Dusts and mists) Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
2 Skin corrosion/irritation Not classified
-
-
- - Based on the description in the report on rabbit skin irritation tests performed in accordance with OECD TG404 (CERI-NITE Hazard Assessment No.78 (2005)): 72 hour application of the substance (the test material content: 97%) "showed no evidence of irritation."
FY2006 GHS Classification Manual (10 Feb, 2006)
3 Serious eye damage/eye irritation Category 1


Danger
H318 P305+P351+P338
P280
P310
Based on the description in the report on rabbit eye irritation tests performed in accordance with OECD TG405 (CERI-NITE Hazard Assessment No.78 (2005)): "severe irritation." Although classified as Category 1-2A in the absence of data on reversibility, the substance should be placed in Category 1 from the viewpoint of safety.
FY2006 GHS Classification Manual (10 Feb, 2006)
4 Respiratory sensitization Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
4 Skin sensitization Not classified
-
-
- - Based on three epidemiological case reports that provide no evidence of skin sensitization in humans (CERI-NITE Hazard Assessment No.78 (2005)) along with negative results of guinea pig skin sensitization tests performed according to Maximization Method. FY2006 GHS Classification Manual (10 Feb, 2006)
5 Germ cell mutagenicity Classification not possible
-
-
- - Based on the absence of data on multi-generation mutagenicity tests, germ/somatic cell mutagenicity tests in vivo and germ/somatic cell genotoxicity tests in vivo, and no positive data on mutagenicity tests in vitro (several indices), described in CERI-NITE Hazard Assessment No.78 (2005) and SIDS (1996).
FY2006 GHS Classification Manual (10 Feb, 2006)
6 Carcinogenicity Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)
7 Reproductive toxicity Category 2


Warning
H361 P308+P313
P201
P202
P280
P405
P501
Based on the evidence of reduced fertility of parental animals and reduced viability of pups at doses producing parental toxicity (or in the absence of data on parental toxicity) in rat reproductive toxicity studies and mouse teratogenicity studies, described in CERI-NITE Hazard Assessment No.78 (2005).
FY2006 GHS Classification Manual (10 Feb, 2006)
8 Specific target organ toxicity - Single exposure Classification not possible
-
-
- - Insufficient data available FY2006 GHS Classification Manual (10 Feb, 2006)
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - Insufficient data available FY2006 GHS Classification Manual (10 Feb, 2006)
10 Aspiration hazard Classification not possible
-
-
- - No data available FY2006 GHS Classification Manual (10 Feb, 2006)

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Category 1


Warning
H400 P273
P391
P501
It was classified into Category 1 from 48 hours LC50=0.16mg/L of the crustacea (Daphnia magna) (CERI/NITE Hazard Assessment Report (preliminary version), 2006). FY2006 GHS Classification Manual (10 Feb, 2006)
11 Hazardous to the aquatic environment Long term (Chronic) Category 1


Warning
H410 P273
P391
P501
Although acute toxicity is Category 1 and bio-accumulation is low (BCF=13(CERI/NITE Hazard Assessment Report (preliminary version), 2006)), since there was no rapidly degrading (the decomposition by BOD: 0%(Existing Chemical Safety Inspections Data)), it was classified into Category 1. FY2006 GHS Classification Manual (10 Feb, 2006)
12 Hazardous to the ozone layer -
-
-
- - - - -


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.

To GHS Information