Item | Information |
---|---|
CAS RN | 65997-15-1 |
Chemical Name | Portland Cement (not containing asbestos, crystalline silica < 1% ) |
Substance ID | m-nite-65997-15-1_v1 |
Download of Excel format | Excel file |
Item | Information |
---|---|
Guidance used for the classification (External link) | To Guidance List |
UN GHS document (External link) | To UN GHS document |
FAQ(GHS classification results by the Japanese Government) | To FAQ |
List of Information Sources (Excel file) | List of Information Sources |
List of Definitions/Abbreviations | Definitions/Abbreviations |
Sample Label by MHLW (External link) | MHLW Website (in Japanese Only) |
Sample SDS by MHLW (External link) | MHLW Website (in Japanese Only) |
OECD/eChemPortal (External link) | To OECD/eChemPortal (External link) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Explosives | Not classified (Not applicable) |
- |
- | - | It is estimated that there are no chemical groups present in the molecule associated with explosive properties. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
2 | Flammable gases | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
3 | Aerosols | Not classified (Not applicable) |
- |
- | - | Not an aerosol product. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
4 | Oxidizing gases | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
5 | Gases under pressure | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
6 | Flammable liquids | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
7 | Flammable solids | Not classified |
- |
- | - | It is not combustible (ICSC (2001)). | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
8 | Self-reactive substances and mixtures | Not classified (Not applicable) |
- |
- | - | It is estimated that there are no chemical groups present in the molecule associated with explosive or self-reactive properties | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
9 | Pyrophoric liquids | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
10 | Pyrophoric solids | Not classified |
- |
- | - | It is not combustible (ICSC (2001)). | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
11 | Self-heating substances and mixtures | Not classified |
- |
- | - | It is not combustible (ICSC (2001)). | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
12 | Substances and mixtures which, in contact with water, emit flammable gases | Not classified |
- |
- | - | Solidifying in mixing with water is the ordinary use, and evolution of dangerous gasses is not observed at that time. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
13 | Oxidizing liquids | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
14 | Oxidizing solids | Classification not possible |
- |
- | - | It is estimated to be an inorganic compound that does not contain halogen and contains oxygen, but the classification is not possible due to no data. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
15 | Organic peroxides | Not classified (Not applicable) |
- |
- | - | It is an inorganic compound. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
16 | Corrosive to metals | Classification not possible |
- |
- | - | No established test method suitable for solid substances. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
17 | Desensitized explosives | - |
- |
- | - | - | - | - |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Acute toxicity (Oral) | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Dermal) | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Inhalation: Gases) | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Inhalation: Vapours) | Not classified (Not applicable) |
- |
- | - | "Solids" according to GHS definition. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
1 | Acute toxicity (Inhalation: Dusts and mists) | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
2 | Skin corrosion/irritation | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
3 | Serious eye damage/eye irritation | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
4 | Respiratory sensitization | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
4 | Skin sensitization | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
5 | Germ cell mutagenicity | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
6 | Carcinogenicity | Classification not possible |
- |
- | - | It is reported that in multiple epidemiological studies on workers handling concrete and cement and cement plant workers who inhaled dust of this substance, increased mortality from lung cancer or cancers of other organs (bladder, stomach, colorectal cancers, and so on) or increased Standardized Incidence Ratios (SIR) was observed. On the other hand, it is reported that an increase in cancers including lung cancer and cancers of other organs was not found, and in general, results of correlation analysis between the cancer incidence and exposure concentrations are lacking (ACGIH (7th, 2010)). Because not all study reports assessed respiratory system cancer by excluding the effects of smoking sufficiently, and because data on carcinogenic effects by exposure to this substance lack consistency and constitute insufficient evidence for A3 classification, ACGIH classified this substance (Portland Cement containing no asbestos and <1% crystalline silica) in A4 (ACGIH (7th, 2010)). Because of no carcinogenicity evaluation conducted by other international organization other than this, from the above, the substance was classified as "Classification not possible" in this hazard class due to lack of data. |
FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
7 | Reproductive toxicity | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
8 | Specific target organ toxicity - Single exposure | Category 3 (Respiratory tract irritation) |
Warning |
H335 | P304+P340 P403+P233 P261 P271 P312 P405 P501 |
It is reported that this substance is irritating to the respiratory tract (ACGIH (7th, 2010)), but no other information. From the above, it was classified in Category 3 (respiratory tract irritation). |
FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
9 | Specific target organ toxicity - Repeated exposure | Category 1 (respiratory organs) |
Danger |
H372 | P260 P264 P270 P314 P501 |
It is reported that in an inhalation route, benign pneumoconiosis occurs in humans, and bronchitis, dyspnea, coughing, phlegm, emphysema, and chest pains are observed. (ACGIH (7th, 2010), DFGOT vol. 11 (1998)) There is no useful information on experimental animals. Therefore, because respiratory organs are considered to be target organs, and signs were observed in humans, the substance was classified in Category 1 (respiratory organs). |
FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
10 | Aspiration hazard | Classification not possible |
- |
- | - | Due to lack of data, the classification is not possible. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
11 | Hazardous to the aquatic environment Short term (Acute) | Classification not possible |
- |
- | - | No data. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
11 | Hazardous to the aquatic environment Long term (Chronic) | Classification not possible |
- |
- | - | No data. | FY2015 | GHS Classification Guidance for the Japanese Government (FY2013 revised edition (Ver. 1.1)) |
12 | Hazardous to the ozone layer | Classification not possible |
- |