Item | Information |
---|---|
CAS RN | 79-36-7 |
Chemical Name | dichloroacetyl chloride |
Substance ID | m-nite-79-36-7_v1 |
Download of Excel format | Excel file |
Item | Information |
---|---|
Guidance used for the classification (External link) | To Guidance List |
UN GHS document (External link) | To UN GHS document |
FAQ(GHS classification results by the Japanese Government) | To FAQ |
List of Information Sources (Excel file) | List of Information Sources |
List of Definitions/Abbreviations | Definitions/Abbreviations |
Sample Label by MHLW (External link) | MHLW Website (in Japanese Only) |
Sample SDS by MHLW (External link) | MHLW Website (in Japanese Only) |
OECD/eChemPortal (External link) | To OECD/eChemPortal (External link) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Explosives | Not classified (Not applicable) |
- |
- | - | There are no chemical groups associated with explosive properties present in the molecules. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
2 | Flammable gases | Not classified (Not applicable) |
- |
- | - | Liquid (room temperature) | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
3 | Aerosols | Not classified (Not applicable) |
- |
- | - | Not aerosol products. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
4 | Oxidizing gases | Not classified (Not applicable) |
- |
- | - | Liquid (room temperature) | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
5 | Gases under pressure | Not classified (Not applicable) |
- |
- | - | Liquid (room temperature) | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
6 | Flammable liquids | Category 4 |
Warning |
H227 | P370+P378 P210 P280 P403 P501 |
Its flash point of 66degC (NFPA (13th, 2002)) is equivalent to that of Category 4. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
7 | Flammable solids | Not classified (Not applicable) |
- |
- | - | Liquid (room temperature) | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
8 | Self-reactive substances and mixtures | Not classified (Not applicable) |
- |
- | - | There are no chemical groups present in the molecule associated with explosive or self-reactive properties. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
9 | Pyrophoric liquids | Not classified |
- |
- | - | Its autoignition point is 585degC (ICSC (J) (1997)), which is above 70degC. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
10 | Pyrophoric solids | Not classified (Not applicable) |
- |
- | - | Liquid (room temperature) | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
11 | Self-heating substances and mixtures | Classification not possible |
- |
- | - | Test methods applicable to liquid substances are not available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
12 | Substances and mixtures which, in contact with water, emit flammable gases | Not classified (Not applicable) |
- |
- | - | The chemical structure of the substance does not contain metals or metalloids (B, Si, P, Ge, AS, Se, Sn, Sb, Te, Bi, Po, At). | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
13 | Oxidizing liquids | Not classified (Not applicable) |
- |
- | - | The substance is an organic compound containing not fluorine, but chlorine and oxygen, which are chemically bonded only to carbon and hydrogen. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
14 | Oxidizing solids | Not classified (Not applicable) |
- |
- | - | Liquid (room temperature) | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
15 | Organic peroxides | Not classified (Not applicable) |
- |
- | - | Organic compounds containing no bivalent -O-O- structure | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
16 | Corrosive to metals | Classification not possible |
- |
- | - | No data available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
17 | Desensitized explosives | - |
- |
- | - | - | - | - |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
1 | Acute toxicity (Oral) | Classification not possible |
- |
- | - | Classification not possible due to lack of data. As relevant information, it is documented that its LD50 = 2460 mg/kg for rats (RTECS (2007)). However, the datum is List 3 datum, and the original test was performed many years ago (1951). | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
1 | Acute toxicity (Dermal) | Classification not possible |
- |
- | - | Classification not possible due to lack of data. As relevant information, it is documented that its LD50 = 650 microL /kg (= 995mg/kg) for rabits (RTECS (2007)). However, the datum is List 3 datum, and the original test was performed many years ago (1951). | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
1 | Acute toxicity (Inhalation: Gases) | Not classified (Not applicable) |
- |
- | - | Liquid (room temperature) | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
1 | Acute toxicity (Inhalation: Vapours) | Classification not possible |
- |
- | - | Classification not possible due to lack of data. As relevant information, it is documented that its LDLo(4h) = 2000 ppm (= 12 mg/L) for rats (RTECS (2007)). However, the datum is List 3 datum, and the original test was performed many years ago (1951). | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
1 | Acute toxicity (Inhalation: Dusts and mists) | Classification not possible |
- |
- | - | No data available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
2 | Skin corrosion/irritation | Category 1 |
Danger |
H314 | P301+P330+P331 P303+P361+P353 P305+P351+P338 P304+P340 P260 P264 P280 P310 P321 P363 P405 P501 |
It has been documented that in an irritation test using rabbits in which 2 mg of the substance was applied to the skin for 24 hours, the substance was severely irritating (RTECS (2007)). Also, in cases of humans, it has been documented to be a strong irritant to skin and eyes (HSDB (2003)). Thus, the substance was classified into Category 1. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
3 | Serious eye damage/eye irritation | Category 1 |
Danger |
H318 | P305+P351+P338 P280 P310 |
By observation 24 hours after application to rabbit eyes, degrees of irritation of most parts including the cornea were rated 10/10 (the most severe irritation) (HSDB (2003)). Also, It has been documented that in an open irritating test using rabbits in which 50 micrograms of the substance was applied to the eyes, the substance was severely irritating (RTECS (2007)). In addition, in cases of humans, it has been documented to be a strong irritant to skin and eyes (HSDB (2003)). Based on information of animals and humans, the substance was classified into Category 1. As relevant information, the substance is rated C; R35 in EU classification (EU-Annex I (accessed July 2008)). | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
4 | Respiratory sensitization | Classification not possible |
- |
- | - | No data available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
4 | Skin sensitization | Classification not possible |
- |
- | - | No data available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
5 | Germ cell mutagenicity | Classification not possible |
- |
- | - | Since no in vivo test data are available, classification is not possible. As relevant information, results of an Ames test using TA100 and TA98 were negative with metabolic activation and positive without metabolic activation (NTP DB (accessed July 2008)). | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
6 | Carcinogenicity | Classification not possible |
- |
- | - | No data available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
7 | Reproductive toxicity | Classification not possible |
- |
- | - | It has been documented that in an in vivo teratogenicity screening test, rats resulted in reduced fertility and increased early implantation failure (Gangolli (2nd, 1999)). However since these data are List 3 data, and no other data are available, the substance was classified into "Classification not possible" due to lack of data. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
8 | Specific target organ toxicity - Single exposure | Classification not possible |
- |
- | - | No data available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
9 | Specific target organ toxicity - Repeated exposure | Classification not possible |
- |
- | - | Classification not possible due to lack of data. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
10 | Aspiration hazard | Classification not possible |
- |
- | - | No data available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
Hazard class | Classification | Pictogram Signal word |
Hazard statement (code) |
Precautionary statement (code) |
Rationale for the classification | Classification year (FY) | GHS Classification Guidance for the Japanese Government | |
---|---|---|---|---|---|---|---|---|
11 | Hazardous to the aquatic environment Short term (Acute) | Classification not possible |
- |
- | - | No data available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
11 | Hazardous to the aquatic environment Long term (Chronic) | Classification not possible |
- |
- | - | No data available. | FY2008 | GHS Classification Guidance by the Japanese Government (Sep, 2008) |
12 | Hazardous to the ozone layer | - |
- |
- | - | - | - | - |
|