Latest GHS Classification Results by the Japanese Government (edited by NITE)

Japanese



GENERAL INFORMATION
 
Item Information
CAS RN 97-62-1
Chemical Name Ethyl 2-methylpropanoate
Substance ID m-nite-97-62-1_v1
Download of Excel format Excel file

REFERENCE INFORMATION
Item Information
Guidance used for the classification (External link) To Guidance List
UN GHS document (External link) To UN GHS document
FAQ(GHS classification results by the Japanese Government) To FAQ
List of Information Sources (Excel file) List of Information Sources
List of Definitions/Abbreviations Definitions/Abbreviations
Sample Label by MHLW (External link) To Workplace Safety Site (MHLW)
Sample SDS by MHLW (External link) To Workplace Safety Site (MHLW)
OECD/eChemPortal (External link) To OECD/eChemPortal (External link)

PHYSICAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Explosives Not classified (Not applicable)
-
-
- - There are no chemical groups associated with explosive properties present in the molecules. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
2 Flammable gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
3 Aerosols Not classified (Not applicable)
-
-
- - Not aerosol products. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
4 Oxidizing gases Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
5 Gases under pressure Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
6 Flammable liquids Category 2


Danger
H225 P303+P361+P353
P370+P378
P403+P235
P210
P233
P240
P241
P242
P243
P280
P501
Classified into Category 2 since flash point 13 degC (closed-cup) (GESTIS (access on Oct. 2009)) is <23 degC and initial boiling point 110.1 degC (Lide (88th, 2008)) is >35 degC. The substance is classified into Class 3, PG II in UNRTDG (UN2385). FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
7 Flammable solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
8 Self-reactive substances and mixtures Not classified (Not applicable)
-
-
- - There are no chemical groups present in the molecule associated with explosive or self-reactive properties. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
9 Pyrophoric liquids Not classified
-
-
- - Auto-ignition point is 463 degC (Hommel (1996)) exceeding 70 degC. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
10 Pyrophoric solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
11 Self-heating substances and mixtures Classification not possible
-
-
- - Test methods applicable to liquid substances are not available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
12 Substances and mixtures which, in contact with water, emit flammable gases Not classified (Not applicable)
-
-
- - The chemical structure of the substance does not contain metals or metalloids (B, Si, P, Ge, As, Se, Sn, Sb, Te, Bi, Po, At). FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
13 Oxidizing liquids Not classified (Not applicable)
-
-
- - The substance is an organic compound containing oxygen (but not fluorine or chlorine) which is chemically bonded only to carbon. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
14 Oxidizing solids Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
15 Organic peroxides Not classified (Not applicable)
-
-
- - Organic compounds containing no bivalent -O-O- structure FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
16 Corrosive to metals Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
17 Desensitized explosives -
-
-
- - - - -

HEALTH HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
1 Acute toxicity (Oral) Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
1 Acute toxicity (Dermal) Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
1 Acute toxicity (Inhalation: Gases) Not classified (Not applicable)
-
-
- - Liquid (GHS definition) FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
1 Acute toxicity (Inhalation: Vapours) Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
1 Acute toxicity (Inhalation: Dusts and mists) Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
2 Skin corrosion/irritation Classification not possible
-
-
- - Classification not possible due to lack of data. As information in a document in List 3, there is a report of "mild" irritating in a Draize test where 500 mg of the substance was applied to the skin of rabbits for 24-hour (RTECS (1997)). FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
3 Serious eye damage/eye irritation Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
4 Respiratory sensitization Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
4 Skin sensitization Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
5 Germ cell mutagenicity Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
6 Carcinogenicity Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
7 Reproductive toxicity Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
8 Specific target organ toxicity - Single exposure Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
9 Specific target organ toxicity - Repeated exposure Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
10 Aspiration hazard Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)

ENVIRONMENTAL HAZARDS
Hazard class Classification Pictogram
Signal word
Hazard statement
(code)
Precautionary statement
(code)
Rationale for the classification Classification year (FY) GHS Classification Guidance for the Japanese Government
11 Hazardous to the aquatic environment Short term (Acute) Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
11 Hazardous to the aquatic environment Long term (Chronic) Classification not possible
-
-
- - No data available. FY2009 GHS Classification Guidance by the Japanese Government (March, 2009)
12 Hazardous to the ozone layer -
-
-
- - - - -


NOTE:
  • GHS Classification Result by the Japanese Government is intended to provide a reference for preparing a GHS label or SDS for users. To include the same classification result in a label or SDS for Japan is NOT mandatory.
  • Users can cite or copy this classification result when preparing a GHS label or SDS. Please be aware, however, that the responsibility for a label or SDS prepared by citing or copying this classification result lies with users.
  • This GHS classification was conducted based on the information sources and the guidance for classification and judgement which are described in the GHS Classification Guidance for the Japanese Government etc. Using other literature, test results etc. as evidence and including different content from this classification result in a label or SDS are allowed.
  • Hazard statement and precautionary statement will show by hovering the mouse cursor over a code in the column of "Hazard statement" and "Precautionary statement," respectively. In the excel file, both the codes and statements are provided.
  • A blank or "-" in the column of "Classification" denotes that a classification for the hazard class was not conducted in the year.
  • An asterisk “*” in the column of “Classification” denotes that “Not classified (or No applicable)” and/or “Classification not possible” is applicable. Details are described in the column of “Rationale for the classification”. If no English translation is available for “Rationale for the classification,” please refer to the Japanese version of the results.