Biological Resource Center, NITE (NBRC)

Mass Spectrometer Introduction

日本語で表示

Using protein analysis technology developed over many years, we are investigating the causes of products that have caused allergic accidents and examining technical standards and evaluation methods for biomolecule-related products in NITE Biological Resource Center (NBRC). The mass spectrometers used for the analysis are introduced below.
Laboratory photo

Mass Spectrometers used for Analysis

The analysis is performed using time-of-flight mass spectrometer (TOF-MS), high performance liquid chromatograph mass spectrometer (LC/MS) and gas chromatograph mass spectrometer (GC/MS).

Time-Of-Flight Mass Spectrometer (TOF-MS)

Matrix-Assisted Laser Desorption Ionization-Time-Of-Flight Mass Spectrometer (MALDI-TOF-MS)

[Model]
Bruker Daltonics: autoflex speed

[Application]
Fungi in Air Conditioners
 

Matrix-Assisted Laser Desorption Ionization-Tandem Time-Of-Flight Mass Spectrometer (MALDI-TOF/TOF-MS)

[Model]
Bruker Daltonics: ultraflex TOF/TOF

[Application]
Identification of Cashmere Fibers
Proteome Projects (DBRP)

High Performance Liquid Chromatograph Mass Spectrometer (LC/MS)

Orbitrap Mass Spectrometer (OT-MS)

[Model]
Thermo Scienitific:
Orbitrap Exploris 240 /FAIMS Pro Duo (nanoESI)
nano LC (AMR: Zaplous U3000-PAL System)

[Application]
Fungi in Air Conditioners

Linear Ion Trap Mass Spectrometer (LIT-MS)

[Model]
Thermo Scienitific: LTQ XL /ETD (nanoESI)
nano LC (AMR: Zaplous U3000-PAL System)

[Application]
Fungi in Air Conditioners
Identification of Cashmere Fibers
Hydrolyzed Wheat Proteins
Proteome Projects (DBRP)
 

Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR-MS)

[Model]
Bruker Daltonics: solariX 7T (ESI, APCI, APPI)
UHPLC (JASCO: X-LC)
HPLC (JASCO: EXTREMA 4000 Model Inert type)
HPLC (Shimadzu: Prominence)

[Application]
Microbial Carotenoids (DBRP)
Identification of Cashmere Fibers
Azo Dyes
Dermopathy Accidents
Degraded Kerosene
 

Triple Quadrupole Mass Spectrometer (QqQ-MS)

[Model]
Waters: Quattro Premier XE (ESI, APCI)
HPLC (Waters: 1525 Binary)
semi micro HPLC (JASCO: PU-4185-Binary)

[Application]
Identification of Cashmere Fibers
Azo Dyes
Dermopathy Accidents
 

Single Quadrupole Mass Spectrometer (Q-MS)

[Model]
Shimadzu: LCMS-2020 (ESI, APCI)
UHPLC (Shimadzu: Nexera XR)

[Application]
Identification of Cashmere Fibers
Dermopathy Accidents

[Term]
ESI: Electrospray ionization
APCI: Atmospheric pressure chemical ionization
APPI: Atmospheric pressure photoionization

Gas Chromatograph Mass Spectrometer (GC/MS)

Double Focusing Mass Spectrometer (EB-MS)

[Model]
JEOL: MStation JMS-700 (EI, CI)
GC (Agilent: 8890 GC system)

[Application]
Azo Dyes
Dermopathy Accidents

[Term]
EI: Electron ionization
CI: Chemical ionization

Back to top

Analysis Results

Analysis results from mass spectrometers are available to be downloaded from the DBRP (Data and Biological Resource Platform).

Contact us

 Analysis Technology Division,  Biological Resource Center,  National Institute of Technology and Evaluation
Phone number:+81-3-3481-1936
Fax number:+81-3-3481-8424
Address:2-49-10 Nishihara, Shibuya-ku, Tokyo 1510066, Japan MAP
Contact Form